Deviation of DBS Recording Microelectrodes during Insertion Assessed by Intraoperative CT

Author:

Massager Nicolas,Nguyen AnthonyORCID,Pouleau Henri-BenjaminORCID,Dethy Sophie,Morelli Daniele

Abstract

Introduction: Intraoperative microelectrodes recording with the Ben Gun microdrive system are often used during DBS surgery. An accurate location of these microelectrodes will directly influence the interest of this recording. We have studied the imprecision of implantation of these microelectrodes. Methods: We have analyzed the stereotactic position of 135 microelectrodes implanted with the Ben Gun microdrive during DBS surgery of 16 patients with advanced Parkinson’s disease. An intracranial CT was obtained and integrated to a stereotactic planification system. We recorded the stereotactic coordinates of the 5 microelectrodes inserted simultaneously in a cross-shape. The coordinates of each microelectrode were compared with coordinates of the other 4 electrodes inserted simultaneously with the Ben Gun and visible on the same iCT image. Thus, this procedure avoids errors from image fusion and from brain shift. We calculate (1) the three-dimensional Euclidian deviation of microelectrodes, (2) the deviation in X- and Y-axes on reconstructed probe’s eye view MR images, and (3) the deviation from the 2-mm theoretical distance between the central electrode and 4 satellite microelectrodes. Results: The median deviation was 0.64 mm in 3-D and 0.58 mm in 2-D probe’s eye view. Satellite electrodes were located from the central electrode theoretically at 2.0 mm and practically within the range 1.9–2.1 mm, 1.5–2.5 mm, 1.0–3.0 mm, and 0.5–3.5 mm for, respectively, 9.3%, 53.7%, 88.0%, and 98.1%, thus highlighting the significant deviation from the theoretical distance. Position imprecisions were similar for the 4 satellite microelectrodes. The imprecision was similar in X-axis and Y-axes and statistically less in Z-axis. For bilateral implantation, the second implantation of the same patient was not associated with a greater risk of deviation of the microelectrodes than for the first side implanted. Conclusion: A significant percentage of microelectrodes for MER can deviate substantially from their theoretical target during DBS procedures. An iCT can be used to estimate the potential deviation of microelectrodes and improve the interpretation of MER during the procedure.

Publisher

S. Karger AG

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3