An Algorithm for Automated Measurement of Kinetic Tremor Magnitude Using Digital Spiral Drawings

Author:

Longardner Katherine,Shen Qian,Tang Bin,Wright Brenton A.,Kundu Prantik,Nahab Fatta B.

Abstract

Introduction: Essential tremor is a common movement disorder. Numerous validated clinical rating scales exist to quantify essential tremor severity by employing rater-dependent visual observation but have limitations, including the need for trained human raters and the lack of precision and sensitivity compared to technology-based objective measures. Other continuous objective methods to quantify tremor amplitude have been developed, but frequently provide unitless measures (e.g., tremor power), limiting real-world interpretability. We propose a novel algorithm to measure kinetic tremor amplitude using digital spiral drawings, applying the V3 framework (sensor verification, analytical validation, and clinical validation) to establish reliability and clinical utility. Methods: Archimedes spiral drawings were recorded on a digitizing tablet from participants (n = 7) enrolled in a randomized placebo control double-blinded crossover pilot trial evaluating the efficacy of oral cannabinoids in reducing essential tremor. We developed an algorithm to calculate the mean and maximum tremor amplitude derived from the spiral tracings. We compared the digitally measured tremor amplitudes to manual measurement to evaluate sensor reliability, determined the test-retest reliability of the digital output across two short-interval repeated measures, and compared the digital measure to kinetic tremor severity graded using The Essential Tremor Rating Assessment Scale (TETRAS) score for spiral drawings. Results: This algorithm for automated assessment of kinetic tremor amplitude from digital spiral tracings demonstrated a high correlation with manual spot measures of tremor amplitude, excellent test-retest reliability, and a high correlation with human ratings of the TETRAS score for spiral drawing severity when the tremor severity was rated “slight tremor” or worse. Discussion: This digital measure provides a simple and clinically relevant evaluation of kinetic tremor amplitude that shows promise as a potential future endpoint for use in clinical trials of essential tremor.

Publisher

S. Karger AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3