The Impact of Patient Factors on Objective Cochlear Implant Verification Using Acoustic Cortical Auditory-Evoked Potentials

Author:

Bogdanov Caris,Mulders Wilhelmina H.A.M.,Goulios Helen,Távora-Vieira Dayse

Abstract

Introduction: Hearing loss is a major global public health issue that negatively impacts quality of life, communication, cognition, social participation, and mental health. The cochlear implant (CI) is the most efficacious treatment for severe-to-profound sensorineural hearing loss. However, variability in outcomes remains high among CI users. Our previous research demonstrated that the existing subjective methodology of CI programming does not consistently produce optimal stimulation for speech perception, thereby limiting the potential for CI users to derive the maximum device benefit to achieve their peak potential. We demonstrated the benefit of utilising the objective method of measuring auditory-evoked cortical responses to speech stimuli as a reliable tool to guide and verify CI programming and, in turn, significantly improve speech perception performance. The present study was designed to investigate the impact of patient- and device-specific factors on the application of acoustically-evoked cortical auditory-evoked potential (aCAEP) measures as an objective clinical tool to verify CI mapping in adult CI users with bilateral deafness (BD). Methods: aCAEP responses were elicited using binaural peripheral auditory stimulation for four speech tokens (/m/, /g/, /t/, and /s/) and recorded by HEARLab™ software in adult BD CI users. Participants were classified into groups according to subjective or objective CI mapping procedures to elicit present aCAEP responses to all four speech tokens. The impact of patient- and device-specific factors on the presence of aCAEP responses and speech perception was investigated between participant groups. Results: Participants were categorised based on the presence or absence of the P1-N1-P2 aCAEP response to speech tokens. Out of the total cohort of adult CI users (n = 132), 63 participants demonstrated present responses pre-optimisation, 37 participants exhibited present responses post-optimisation, and the remaining 32 participants either showed an absent response for at least one speech token post-optimisation or did not accept the optimised CI map adjustments. Overall, no significant correlation was shown between patient and device-specific factors and the presence of aCAEP responses or speech perception scores. Conclusion: This study reinforces that aCAEP measures offer an objective, non-invasive approach to verify CI mapping, irrespective of patient or device factors. These findings further our understanding of the importance of personalised CI rehabilitation through CI mapping to minimise the degree of speech perception variation post-CI and allow all CI users to achieve maximum device benefit.

Publisher

S. Karger AG

Subject

Speech and Hearing,Sensory Systems,Otorhinolaryngology,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3