Bioreactance Cardiac Output Trending Ability in Preterm Infants: A Single Centre, Longitudinal Study

Author:

Van Wyk LizelleORCID,Smith JohanORCID,Lawrenson John,Lombard Carl J.ORCID,de Boode Willem-Pieter

Abstract

<b><i>Introduction:</i></b> It is unknown whether bioreactance (BR) can accurately track cardiac output (CO) changes in preterm neonates. <b><i>Methods:</i></b> A prospective observational longitudinal study was performed in stable preterm infants (&#x3c;37 weeks) during the first 72 h of life. Stroke volume (SV) and CO, as measured by BR and transthoracic echocardiography, were compared. <b><i>Results:</i></b> The mean gestational age (GA) was 31.3 weeks and mean birth weight (BW) was 1,563 g. Overall, 690 measurements were analysed for trending ability by 4-quadrant and polar plots. For non-weight-indexed measurements, 377 (54.6%) lay outside the 5% exclusion zone, the concordance rate was poor (77.2%) with a high mean angular bias (28.6°), wide limits of agreement and a poor angular concordance rate (17.4%). Neither GA, BW nor respiratory support mode affected trending data. Patent ductus arteriosus, postnatal age, and CO level had variable effects on trending data. Trending data for 5 and 10% exclusion zones were also compared. <b><i>Conclusion:</i></b> The ability of BR to track changes in CO is not interchangeable with CO changes as measured by echocardiography. BR, as a trend monitor for changes in CO or SV to determine clinical decisions around interventions in neonatology, should be used with caution.

Publisher

S. Karger AG

Subject

Developmental Biology,Pediatrics, Perinatology, and Child Health

Reference29 articles.

1. Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111(5):1180–92.

2. Jakovljevic DG, Moore S, Hallsworth K, Fattakhova G, Thoma C, Trenell MI. Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise. J Clin Monit Comput. 2012;26(2):63–8.

3. Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15(2):85–91.

4. Critchley LAH, Huang L, Zhang J. Continuous cardiac output monitoring: what do validation studies tell us?. Curr Anesthesiol Rep. 2014 Sep;4(3):242–50.

5. de Boode WP, van der Lee R, Horsberg Eriksen B, Nestaas E, Dempsey E, Singh Y, et al. The role of neonatologist performed echocardiography in the assessment and management of neonatal shock. Pediatr Res. 2018;84(1):57–67.