Using Clinical Audiologic Measures to Determine Cochlear Implant Candidacy

Author:

Reddy Priyanka,Dornhoffer James R.,Camposeo Elizabeth L.,Dubno Judy R.ORCID,McRackan Theodore R.

Abstract

<b><i>Introduction:</i></b> Only a small percentage (6–10%) of patients who are candidates receive cochlear implants (CIs). One potential reason contributing to low usage rates may be confusion regarding which patients to refer for CI evaluation. The extent to which information provided by standard clinical audiologic assessments is sufficient for selecting appropriate CI evaluation referrals is uncertain. The objective of this study is to evaluate the capacity of standard clinical audiologic measures to differentiate CI candidates from noncandidates. <b><i>Method:</i></b> The study design is a retrospective review of a prospectively maintained CI database from a university-based tertiary medical center of 518 patients undergoing CI evaluations from 2012 to 2020. Each ear of each patient was treated as an independent value. Receiver operating characteristic (ROCs) curves were constructed using aided AzBio sentence recognition scores in quiet and aided AzBio +10 dB signal-to-noise ratio scores &#x3c;60% as binary classifiers for CI candidacy. For each ROC, we examined the capacity of multiple pure-tone thresholds, pure-tone average (PTA), and CNC word recognition scores (WRSs) measured under earphones to determine CI candidacy. Area under the curve ROC (AUC-ROC) values were calculated to demonstrate the capacity of each model to differentiate CI candidates from noncandidates. <b><i>Results:</i></b> Variables with the greatest capacity to accurately differentiate CI candidates from noncandidates using aided AzBio in quiet scores were earphone CNC WRS, earphone pure-tone threshold at 1,000 Hz, and earphone PTA (AUC-ROC values = 0.86–0.88). Using aided AzBio +10 scores as the measure for candidacy, only CNC word recognition had a fair capacity to identify candidates (AUC-ROC value = 0.73). Based on the ROCs, a 1,000 Hz pure-tone threshold &#x3e;50 dB HL, PTA &#x3e;57 dB HL, and a monosyllabic WRS &#x3c;60% can each serve as individual indicators for referral for CI evaluations. <b><i>Conclusion:</i></b> The current study provides initial indicators for referral and a first step at developing evidence-based criteria for CI evaluation referral using standard audiologic assessments.

Publisher

S. Karger AG

Subject

Speech and Hearing,Sensory Systems,Otorhinolaryngology,Physiology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3