Development of a Stereotactic Radiosurgery Frame Adapter for a Multichannel MRI Coil

Author:

Kim Byungmok,Chang Yongmin,Choi Hea Jung,Park Ki-Su,Yang Ji-ung,Kim Eunji,Park Seong-HyunORCID

Abstract

<b><i>Background:</i></b> The usage of multichannel brain MRI coils, which have several advantages over single-channel brain coils used for stereotactic radiosurgery (SRS), requires a frame adapter device to fit the frames inside the multichannel brain coils. However, such a frame adapter has not been developed until now. <b><i>Objective:</i></b> to develop an SRS frame adapter for multichannel MRI coils and verify the geometrical accuracy and signal-to-noise ratio (SNR) of the MR images obtained using multichannel MRI coils. <b><i>Methods:</i></b> We fabricated an SRS frame adapter for a 48-channel MRI coil using a three-dimensional (3D) printer. Furthermore, we obtained phantom and human-brain MR images with a 3.0 Tesla MRI scanner using multi- and single-channel coils. Computed tomography (CT) phantom images were also obtained as reference. We compared the coordinate errors of the multi- and single-channel coils to evaluate the geometrical accuracy. Two neurosurgeons measured the coordinates. In addition, we compared the SNR differences between multi- and single-channel coils using the T1- and T2-weighted brain images. <b><i>Results:</i></b> For the CT coordinate measurements, the correlation coefficient <i>r</i> = 1 and <i>p</i> &#x3c; 0.001 with respect to the 3 axes (Δ<i>x</i>, Δ<i>y</i>, and Δ<i>z</i>) and 3D errors (Δ<i>r</i>) showed no interpersonal differences between the 2 neurosurgeons. The results obtained using the T1-weighted images showed that a multichannel coil had smaller coordinate errors in Δ<i>x</i>, Δ<i>y</i>, Δ<i>z</i>, and Δ<i>r</i> than that observed in case of a single-channel coil (<i>p</i> &#x3c; 0.001). In case of the SNR measurements, most of the brain areas showed higher SNRs when using a multichannel coil compared with that observed when using a single-channel coil in the T1- and T2-weighted images. <b><i>Conclusion:</i></b> Compared with single-channel coils, the use of multichannel MRI coils with a newly developed frame adapter is expected to ensure successful SRS treatments with improved geometrical accuracy and SNR.

Publisher

S. Karger AG

Subject

Neurology (clinical),Surgery

Reference24 articles.

1. Chen Y, Godage I, Su H, Song A, Yu H. Stereotactic systems for MRI-guided neurosurgeries: a state-of-the-art review. Ann Biomed Eng. 2019;47(2):335–53.

2. Guo WY. Application of MR in stereotactic radiosurgery. J Magn Reson Imaging. 1998 Mar-Apr;8(2):415–20.

3. Ginat DT, Swearingen B, Curry W, Cahill D, Madsen J, Schaefer PW. 3 Tesla intraoperative MRI for brain tumor surgery. J Magn Reson Imaging. 2014;39(6):1357–65.

4. Kim HY, Lee SI, Jin SJ, Jin SC, Kim JS, Jeon KD. Reliability of stereotactic coordinates of 1.5-tesla and 3-tesla MRI in radiosurgery and functional neurosurgery. J Korean Neurosurg Soc. 2014;55(3):136–41.

5. Larkman DJ, Nunes RG. Parallel magnetic resonance imaging. Phys Med Biol. 2007;52(7):R15.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献