Percutaneous Renal Biopsy Using an 18-Gauge Automated Needle Is Not Optimal

Author:

Sousanieh George,Whittier William L.,Rodby Roger A.,Peev Vasil,Korbet Stephen M.

Abstract

<b><i>Background:</i></b> As percutaneous renal biopsies (PRBs) are increasingly performed by radiologists, an increase in the use of 18-gauge automated needle stands to compromise adequacy. We compare the adequacy and safety of PRB with 14-, 16-, and 18-gauge automated needles. <b><i>Methods:</i></b> PRB of native (N-592) and transplant (T-1,023) kidneys was performed from January 2002 to December 2019 using real-time ultrasound. Baseline clinical and laboratory data, biopsy data (number of cores, total glomeruli, and total glomeruli per core), and outcome (hematoma on renal US at 1-h, complications, and transfusion) were collected prospectively. PRB with N14g (337) versus N16g (255) and T16g (892) versus T18g (131) needles were compared. A <i>p</i> value of &#x3c;0.05 was significant. <b><i>Results:</i></b> PRB with an 18-g needle yielded the lowest number of total glomeruli per biopsy (N14g vs. N16g: 33 ± 13 vs. 29 ± 12, <i>p</i> &#x3c; 0.01 and T16g vs. T18g: 34 ± 16 vs. 21 ± 11, <i>p</i> &#x3c; 0.0001), significantly fewer total glomeruli per core (T16g vs. T18g: 12.7 ± 6.4 vs. 9.6 ± 5.0, <i>p</i> &#x3c; 0.001 and N16g vs. T18g: 14.2 ± 6.3 vs. 9.6 ± 5.0, <i>p</i> &#x3c; 0.001). A hematoma by renal US 1-h post-PRB was similar for native (14g–35% vs. 16g–29%, <i>p</i> = 0.2), and transplant biopsies (16g–10% vs. 18g–9%, <i>p</i> = 0.9) and the complication rate for native (14g–8.9% vs. 16g–7.1%, <i>p</i> = 0.5), transplant biopsies (16g–4.6% vs. 18g–1.5%, <i>p</i> = 0.2) and transfusion rate for native (14g–7.7% vs. 16g–5.8%, <i>p</i> = 0.4), and transplant biopsies (16g–3.8% vs. 18g–0.8%, <i>p</i> = 0.1) were similar irrespective of needle size. <b><i>Conclusions:</i></b> PRB of native and transplant kidneys with the use of a 16-gauge needle provides an optimal sample. However, our experience in transplant biopsies suggests the use of an 18-gauge needle stands to jeopardize the diagnostic accuracy of the PRB while not improving safety.

Publisher

S. Karger AG

Subject

Nephrology

Reference28 articles.

1. Korbet SM. Percutaneous renal biopsy. Semin Nephrol. 2002;22(3):254–67.

2. Wang HJ, Kjellstrand CM, Cockfield SM, Solez K. On the influence of sample size on the prognostic accuracy and reproducibility of renal transplant biopsy. Nephrol Dial Transplant. 1998;13(1):165–72.

3. Oberholzer M, Torhorst J, Perret E, Mihatsch MJ. Minimum sample size of kidney biopsies for semiquantitative and quantitative evaluation. Nephron. 1983;34(3):192–5.

4. Madaio MP. Renal biopsy. Kidney Int. 1990;38(3):529–43.

5. Corwin HL, Schwartz MM, Lewis EJ. The importance of sample size in the interpretation of the renal biopsy. Am J Nephrol. 1988;8(2):85–9.

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3