Noninvasive Hemodynamic Profiles during Hemodialysis in Patients with and without Heart Failure

Author:

Lin Ying-Kuang,Kao Chih-Chin,Tseng Chi-Ho,Hsu Ching-En,Lin Yi-Je,Chen You-Chuan,Lin Chen,Huang Chun-Yao

Abstract

Background: Although the dynamics of blood pressure (BP) during dialysis provide information related to the control system, the prognosis and relationships between temporal changes in intradialytic hemodynamic regulation, BP, and decreased cardiac function remain largely unclear. Methods: Hemodynamic parameters, including heart rate (HR), stroke volume (SV), cardiac index, and systemic vascular resistance index, were recorded using a noninvasive hemodynamic device on a beat-by-beat basis in 40 patients on dialysis who were divided into three groups, i.e., those with and without BP lability and those with heart failure (HF). Statistical measurements, including mean, standard deviation, coefficient of variation (CV), and index of nonrandomness of each hemodynamic parameter were derived from the three different phases divided equally during dialysis and compared using 3×3 two-way mixed-model analysis of variance to determine the effects of the different stages of hemodialysis (HD), cardiac function, and intradialytic changes in BP on the hemodynamic parameters. In addition, multivariate Cox regression was performed to determine the association between the changes in the derived parameters and BP lability. Results: The average SV tended to decrease during HD in all groups (p = 0.041). A significant decrease was observed in the CV of SV between the first two stages of HD in patients with labile BP and HF when compared to those without labile BP (p = 0.037). Significant interactions between group and stage of the index of nonrandomness for HR were also noted; this index was significantly higher in patients without labile BP than in those with labile BP or HF (p = 0.048). A higher difference between the early and middle stages of HD for nonrandomness indexes of HR was an independent predictor of reduced BP lability during HD (HR = 0.844, 95% confidence interval 0.722–0.987, p = 0.034). Conclusions: Increases in the CV of SV and the index of nonrandomness for HR during early-stage HD in response to decreased SV may be associated with better BP control during HD. This finding suggests that patients with more structurally meaningful hemodynamic control have a more favorable cardiovascular outcome.

Publisher

S. Karger AG

Subject

Urology,Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3