Bone-Anchored Hearing Devices for Single-Sided Deafness: A New Preoperative Evaluation Protocol and Widening of Indications Proposal

Author:

Cantore ItaloORCID,Cianfrone Francesca,Tauro Francesco,Bevilacqua Pio,De Carli Paolo,Bianco Francesco,Di Carmine Francesca,Ruscito Paolo

Abstract

Introduction: Bone-anchored hearing devices (BAHD) are well-known good solution for single-sided deafness (SSD). Despite power extension of recently introduced BAHD with implanted active transducer, with indications up to 65 dB Hl of bone conduction (BC) threshold on the implanted side, their indications for SSD still remain better than 25 dB on the good ear, with regards to bone conduction thresholds. The aim of this study was to assess the possibility to enlarge BAHD indications for SSD by means of a newly proposed candidacy evaluation protocol, which includes a new software-aided method. Methods: 20 SSD patients (mean age 56 years, 9 females, and 11 males) were divided into two groups: group A (10 patients, BC <25 dB Hl on the hearing side) and group B (10 patients, BC between 25 and 35 dB Hl). Recipients were submitted to bisyllabic words speech audiometry in silence and to authors’ newly proposed IFastSRT50 test by means of software which shift noise intensity of a single word list on the basis of correct recipient recognition responses. A sound speaker for signal (bisyllabic words) and noise (babble) was disposed at 1 m from the deaf side of the patient. An earphone covering only the good ear of the recipient was used in order to perform its air conduction masking with white noise. A BAHD test device was disposed on the mastoid of the deaf side. Both signal and masking intensities were set to 55 dB SPL in order to mask airway conduction on the good ear without masking its bone way interaural conduction from the BAHD tester. Results: With BAHD tester turned off, no recognition was detected. Speech audiometry with BAHD tester turned on revealed mean values of 92% for group A and 89% for group B, with a difference of 3.0% (χ2 = 0.285 and p = 0.5935). As for IFastSRT50 with BAHD tester turned on, mean signal-to-noise ratio value to obtain 50% of recognition was −6.89 for group A and −6, with a difference of 0.89 (t = 1,201 and p = 0.2453). Conclusion: BAHD are confirmed to be a good solution for SSD cases. The absence of statistically significant differences in our two tested groups suggests that newer implanted active transducer device indications should be extended up to 35 dB Hl on the hearing ear. The IFastSRT50 is a reliable and quick method to enhance preoperative candidacy evaluation.

Publisher

S. Karger AG

Subject

Speech and Hearing,Sensory Systems,Otorhinolaryngology,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3