A Novel Mask with Selective Ports for Inflow and Outflow Reduces CO<sub>2</sub> Rebreathing during Non-Invasive Ventilation: A Physiological Study in Healthy Volunteers

Author:

Rezoagli Emanuele,Signori DavideORCID,Grassi Alice,Rabboni Francesca,Lucchini AlbertoORCID,Bellani Giacomo,Foti GiuseppeORCID

Abstract

<b><i>Background:</i></b> CO<sub>2</sub> rebreathing is one of the risks associated with noninvasive ventilation (NIV), possibly contributing to failure. In a bench study, we showed that a novel mask design, with separate limbs for inflow and outflow gases, significantly reduced CO<sub>2</sub> rebreathing in different ventilation settings. <b><i>Objectives:</i></b> The study aimed to test whether a new mask design could 1) reduce CO<sub>2</sub> rebreathing in healthy volunteers during NIV (phase 1) and 2) reduce minute ventilation (phase 2). <b><i>Materials and Methods:</i></b> Healthy volunteers were randomly assigned to NIV using two masks in a crossover design: a traditional single-limb mask for inflow and outflow gases and a mask with two separated limbs. In phase 1, six ventilation settings were tested for each mask: CPAP (PEEP 5 cmH<sub>2</sub>O) and pressure support ventilation (PSV, PS Level 5 cmH<sub>2</sub>O) using a mechanical ventilator with a bias flow of 8 or 20 L/min; free-flow CPAP (PEEP 5 cmH<sub>2</sub>O) with 60 or 90 L/min of gas flow. A nasal cannula was inserted in one nostril of the volunteers and connected to a CO<sub>2</sub> gas analyzer to measure CO<sub>2</sub> during the respiratory cycle. In phase 2, volunteers underwent a prolonged time of ventilation in CPAP 90 L/min and PSV with 20 L/min of bias flow. During free-flow CPAP, electrical impedance tomography was used to record the change in impedance during tidal breathing and then estimate tidal volume. <b><i>Results:</i></b> Ten healthy adults were enrolled in phase 1, and 8 volunteers in phase 2. CO<sub>2</sub> during inspiration was significantly lower in each setting with the two-limb versus the one-limb mask (<i>p</i> &#x3c; 0.001). The maximum CO<sub>2</sub> reduction was observed in the continuous-flow CPAP settings. EtCO<sub>2</sub> was lower with the two-limb mask compared to the one-limb mask (<i>p</i> &#x3c; 0.001). However, no difference in minute ventilation was observed between the two masks. <b><i>Conclusion:</i></b> The new mask design with two ports for inhaled and exhaled gases reduced the amount of CO<sub>2</sub> rebreathing in all tested ventilation settings. The CO<sub>2</sub> rebreathing reduction did not decrease minute ventilation in healthy volunteers.

Publisher

S. Karger AG

Subject

Pulmonary and Respiratory Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3