Safety and Considerations of the Anaesthetic Management during Bronchoscopic Lung Volume Reduction Treatments

Author:

Roodenburg Sharyn A.,Barends Clemens R.M.ORCID,Krenz Grita,Zeedijk Eelco J.,Slebos Dirk-JanORCID

Abstract

<b><i>Background:</i></b> Different bronchoscopic lung volume reduction approaches are available for a select group of patients with advanced COPD. General anaesthesia is the recommended method of sedation during these procedures. However, this patient population is at an increased risk of anaesthetic complications, and the best approach to general anaesthesia and mechanical ventilation is unknown. <b><i>Objectives:</i></b> The aims of this study were to describe the anaesthetic management techniques used during bronchoscopic lung volume reduction procedures and to investigate the number of anaesthesia-related events. <b><i>Methods:</i></b> Data were retrospectively collected from all endobronchial valve and lung volume reduction coil procedures performed between January 2018 and March 2020 in our hospital. Primary outcomes measures were anaesthetic technique including airway management; ventilation mode and settings; and the incidence of anaesthesia-related events, classified as catastrophic, severe, significant, or moderate. <b><i>Results:</i></b> 202 procedures were included. One procedure was performed under procedural sedation, 198 (98%) under general anaesthesia with endotracheal intubation, and 3 (1.5%) under general anaesthesia with laryngeal mask airway. Volume-controlled ventilation was used in 64% of the procedures and pressure-controlled in 36%. Patients were ventilated with a median respiration rate of 9.9 (IQR: 9.6–10.6) breaths per minute, mean tidal volume of 5.8 ± 1.4 mL/kg, and median inspiratory to expiratory (I:E) ratio of 1:2.8 (IQR: 1:2.1–1:3.2). No catastrophic anaesthesia-related events were observed. Hypotension was the most observed anaesthesia-related event. <b><i>Conclusions:</i></b> Despite the presence of advanced COPD, general anaesthesia and mechanical ventilation are well tolerated by patients undergoing endobronchial valve or lung volume reduction coil treatment. This is presumably strongly linked to the strict selection criteria. Other important considerations are using a low respiratory rate, low tidal volume, and high I:E ratio.

Publisher

S. Karger AG

Subject

Pulmonary and Respiratory Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3