Objective Home-Monitoring of Physical Activity, Cardiovascular Parameters, and Sleep in Pediatric Obesity

Author:

Knijff Janine M.ORCID,Houdijk Euphemia C.A.M.,van der Kaay Daniëlle C.M.,van Berkel Youri,Filippini Luc,Stuurman Frederik E.ORCID,Cohen Adam F.ORCID,Driessen Gertjan J.A.,Kruizinga Matthijs D.

Abstract

<b><i>Introduction:</i></b> Clinical research and treatment of childhood obesity is challenging, and objective biomarkers obtained in a home-setting are needed. The aim of this study was to determine the potential of novel digital endpoints gathered by a home-monitoring platform in pediatric obesity. <b><i>Methods:</i></b> In this prospective observational study, 28 children with obesity aged 6–16 years were included and monitored for 28 days. Patients wore a smartwatch, which measured physical activity (PA), heart rate (HR), and sleep. Furthermore, daily blood pressure (BP) measurements were performed. Data from 128 healthy children were utilized for comparison. Differences between patients and controls were assessed via linear mixed effect models. <b><i>Results:</i></b> Data from 28 patients (average age 11.6 years, 46% male, average body mass index 30.9) and 128 controls (average age 11.1 years, 46% male, average body mass index 18.0) were analyzed. Patients were recruited between November 2018 and February 2020. For patients, the median compliance for the measurements ranged from 55% to 100% and the highest median compliance was observed for the smartwatch-related measurements (81–100%). Patients had a lower daily PA level (4,597 steps vs. 6,081 steps, 95% confidence interval [CI] 862–2,108) and peak PA level (1,115 steps vs. 1,392 steps, 95% CI 136–417), a higher nighttime HR (81 bpm vs. 71 bpm, 95% CI 6.3–12.3) and daytime HR (98 bpm vs. 88 bpm, 95% CI 7.6–12.6), a higher systolic BP (115 mm Hg vs. 104 mm Hg, 95% CI 8.1–14.5) and diastolic BP (76 mm Hg vs. 65 mm Hg, 95% CI 8.7–12.7), and a shorter sleep duration (difference 0.5 h, 95% CI 0.2–0.7) compared to controls. <b><i>Conclusion:</i></b> Remote monitoring via wearables in pediatric obesity has the potential to objectively measure the disease burden in the home-setting. The novel endpoints demonstrate significant differences in PA level, HR, BP, and sleep duration between patients and controls. Future studies are needed to determine the capacity of the novel digital endpoints to detect effect of interventions.

Publisher

S. Karger AG

Subject

Health Informatics,Computer Science Applications,Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3