Comparison of Clarus and Optomap Ultra-Widefield Imaging Systems before and after EVO-ICL Implantation in High Myopia

Author:

Han Xiaosong,Xu Yijia,Chen Zhi,Wei Ruoyan,Yang Weiming,Yu Zhiqiang,Wang Xiaoying,Li Meiyan,Zhou Xingtao

Abstract

<b><i>Introduction:</i></b> The aim of this study was to investigate the features of imaging differences between Clarus and Optomap ultra-widefield imaging systems after implantable collamer lens (ICL) implantation. <b><i>Methods:</i></b> This was a non-randomized controlled study. Ninety-two eyes of 46 consecutive patients were enrolled. Full-scale ophthalmological examinations were conducted preoperatively. All patients underwent Clarus (CLARUS 500; Carl Zeiss, Dublin, USA) and Optomap (Daytona; Optos, UK) ultra-wide imaging sequentially under the same circumstance preoperatively and 1 month after EVO-ICL implantation. A single image was acquired from each. D<sub>x</sub> was defined as the distance between the upper furcation of the central retinal artery and the central fovea of macula. Pixels of the optic cup and disc and D<sub>x</sub> as well as the optic cup/disc ratio were calculated and compared on each machine before and after surgery. <b><i>Results:</i></b> All surgeries were uneventful without complications. Safety and efficacy indices were both 100% at 1 month. Values of both optic cup and disc areas were in decrease after surgery with statistically significant differences (<i>p</i> &lt; 0.001), while the cup/disc ratio remained the same (Clarus mean of differences = −0.0028, <i>p</i> = 0.83; Optomap mean of differences = −0.0016, <i>p</i> = 0.76). D<sub>x</sub> of images captured with either machine was statistically significantly decreased (<i>p</i> &lt; 0.001). Differences of both optic cup (<i>p</i> = 0.057) and disc (<i>p</i> = 0.041) areas of Clarus were more obvious than that of Optomap, while only the latter was with statistical significance. Difference of D<sub>x</sub> of Clarus was statistically significantly larger than Optomap. <b><i>Conclusions:</i></b> Display ranges tend to be broadened after EVO-ICL implantation in both Clarus and Optomap ultra-widefield imaging systems, while Clarus shows a wider display range of the two, which encourages the application of Clarus when it comes to the detection of more peripheral retinal lesions.

Publisher

S. Karger AG

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3