Initial Concentrations of miR-1 MicroRNA Precursor and High-Sensitivity Troponin in the Diagnosis of Non-ST Myocardial Infarction among Patients with and Those without Chronic Kidney Disease

Author:

Su Tong,Shao Xiaonan,Zhang Xiaopu,Han Zhijun,Yang Chengjian,Li Xun

Abstract

Background: The early diagnosis of non-ST-segment elevation myocardial infarction (NSTEMI) in patients with chronic kidney disease (CKD) remains a challenge. Methods: The study consecutively enrolled patients who had suffered from chest pain within 3 h whose electrocardiogram had no elevation in the ST segment. CKD was defined as an estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2, and the diagnostic criteria for NSTEMI were defined according to the recommended guideline. Circulating microRNA-1 was collected and determined by quantitative real-time reverse transcription polymerase chain reaction. Results: A total of 456 patients with suspected NSTEMI were included. There were 115 patients in the CKD group, including 67 with NSTEMI, 20 with stable angina, 7 with unstable angina, 18 with heart failure, and 3 with other disorders. Compared with the NSTEMI group, the non-NSTEMI group just had significant differences in microRNA-1 and high-sensitivity cardiac troponin I (hs-cTnI) (both p < 0.05). The relative expression of microRNA-1 was significantly increased in the NSTEMI group as compared with that in the other disease groups (all p < 0.05). A receiver operating characteristic (ROC) curve analysis suggested that microRNA-1 and hs-cTnI had advantages in the early diagnosis of NSTEMI with CKD (AUC [area under the ROC curve] 0.879 and 0.812, respectively, both p < 0.05). Compared with that in the non-CKD group, the accuracy of microRNA-1 was almost as good in the CKD group (84.3 vs. 89.4%, p > 0.05). However, the diagnostic accuracy of hs-cTnI was significantly decreased (79.1 vs. 91.5%, p < 0.05), as was its specificity (75.0 vs. 95.5%, p < 0.05). There was no significant difference in the correlation between microRNA-1 and eGFR (p > 0.05), but a statistically significantly negative correlation between hs-cTnI and eGFR (p < 0.05). Conclusion: Circulating microRNA-1 is capable of early diagnosis of NSTEMI in patients with CKD suffering from chest pain.

Publisher

S. Karger AG

Subject

Urology,Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3