Protein-Bound Uremic Toxins and Inflammation Process in Hemodialysis Patients: Is There a Role for Adsorption Hemodiafiltration?

Author:

Fabbrini Paolo,Vergani Denise,Malinverno Anna,Pieruzzi Federico,Marengo Marita,Merlotti Guido,Medana Claudio,Quercia Alessandro Domenico,Cantaluppi Vincenzo

Abstract

Introduction: Despite major advances in the field of dialysis, there are still some unmet needs such as reducing inflammation through adequate depuration. It is well known that the wide spectrum of pro-inflammatory and pro-atherosclerotic uremic toxins are inefficiently removed by current dialysis techniques. Adsorption seems to be an extra tool to remove toxins, but its effect and optimization have not been widely studied. The aim of this report was to present preliminary results regarding the possibility of performing hemodiafiltration with a highly adsorptive polymethylmethacrylate membrane. Methods: The study was first conducted in 10 patients in which the safety and feasibility of hemodiafiltration with PMMA BG-U 2.1 membrane were tested through measurement of hemolysis indices, transmembrane pressures, and dialysis adequacy. Twenty patients were prospectively observed for 18-month period in which they consecutively underwent standard hemodialysis, standard post-dilution hemodiafiltration, and polymethylmethacrylate-based post-dilution hemodiafiltration. Protein-bound uremic toxins concentrations and inflammatory markers were measured throughout the observed period. Results: HDF-PMMA was inferior to HDF in convective volume, but KT/V was similar, and no differences were noted in operating pressures during the two treatments. During HDF-PMMA period of treatment, we observed a significant reduction of CPR levels, and HDF-PMMA was superior to all other treatments in hepcidin removal even if this did not significantly affect hemoglobin levels. HDF-PMMA could significantly reduce indoxyl sulfate (indoxyl) concentration over a period of 6 months but not for p-cresyl sulfate (p-cresyl). Conclusion: PMMA BG-U 2.1 membrane can be safely and efficiently used in hemodiafiltration. Moreover, as these preliminary results show, adding adsorption properties to convection and diffusion enabled an increased removal of indoxyl uremic toxin associated to a reduction in inflammation markers as CRP and hepcidin without any negative impact on albumin levels.

Publisher

S. Karger AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3