The Agreement of the Nomogram Tool and Ultrasound Biomicroscopy Images in Calculating Ultrasound Cycloplasty Probe Model in Chinese Patients

Author:

Zheng Shaoyang,Wang Dingqiao,Huang Zhihong,Wang Zhenyu,Liu Yuan,Chen LimingORCID,Jin Ling,Tan Yuheng,Lin Mingkai,Zuo Chengguo

Abstract

Purpose: The aim of the study was to compare and explore the agreement between the nomogram tool and ultrasound biomicroscopy (UBM) images method to calculate the ultrasound cycloplasty (UCP) probe model in Chinese glaucoma patients. Methods: Retrospective analysis of Chinese glaucoma patients who visited Zhongshan Ophthalmic Center in Guangzhou from January to December 2019 and were eligible for UCP surgery. Visual acuity, intraocular pressure (IOP), ocular axial length (AL), and horizontal corneal diameter (white to white [WTW]) were measured. UBM images with clear ciliary body imaging and AL and WTW data were sent to trained personnel for probe model measurements. The data calculated by both methods were analyzed using unweighted and weighted κ statistics. The level of agreement refers to Landis and Koch’s guideline for the strength of agreement indicated with weighted κ values. Results: 1,061 eyes of 642 patients were involved, with a mean age of 61.66 ± 11.66 years. Their best-corrected visual acuity converted to logarithm of minimal-angle-of-resolution (logMAR) scores of −0.18–3.00 with a mean value of 0.69 ± 0.77. IOP was 22.0–60.0 mm Hg with a mean of 27.97 ± 5.66 mm Hg. The mean AL and WTW were 22.88 ± 1.33 (19.15–32.14) mm and 11.52 ± 0.49 (10.00–12.90) mm, respectively. The agreement between the two methods was fair (weighted κ = 0.299), matching in 62.86% of eyes (weighted κ = 0.299, κ = 0.264). The agreement in primary open angle glaucoma, acute primary angle-closure glaucoma, chronic primary angle-closure glaucoma, and secondary glaucoma patients was 60.85% (weighted κ = 0.336, κ = 0.301), 65.06% (weighted κ = 0.146, κ = 0.127), 62.26% (weighted κ = 0.204, κ = 0.184), and 57.97% (weighted κ = 0.332, κ = 0.280) of eyes, respectively. Conclusion: The agreement between UBM images and the nomogram tool to calculate the UCP probe model of Chinese patients is at a fair level. The nomogram tool prefers to use larger probes. Improvements to the nomogram tool, such as including data from more ethnic groups and being able to calculate separately for different types of glaucoma, are needed to improve accuracy. The inclusion of parameters or images from more directions of the eye may help measure probe models more accurately for both the nomogram tool and the UBM image measurement.

Publisher

S. Karger AG

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3