Predicting Matrix Test Effectiveness for Evaluating Auditory Performance in Noise Using Pure-Tone Audiometry and Speech Recognition in Quiet in Cochlear Implant Recipients

Author:

Flament Jonathan,De Seta Daniele,Russo Francesca Yoshie,Bestel Julie,Sterkers Olivier,Ferrary Evelyne,Nguyen Yann,Mosnier Isabelle,Torres Renato

Abstract

<b><i>Introduction:</i></b> Auditory performance in noise of cochlear implant recipients can be assessed with the adaptive Matrix test (MT); however, when the speech-to-noise ratio (SNR) exceeds 15 dB, the background noise has any negative impact on the speech recognition. Here, we aim to evaluate the predictive power of aided pure-tone audiometry and speech recognition in quiet and establish cut-off values for both tests that indicate whether auditory performance in noise can be assessed using the Matrix sentence test in a diffuse noise environment. <b><i>Methods:</i></b> Here, we assessed the power of pure-tone audiometry and speech recognition in quiet to predict the response to the MT. Ninety-eight cochlear implant recipients were assessed using different sound processors from Advanced Bionics (<i>n</i> = 56) and Cochlear<sup>TM</sup> (<i>n</i> = 42). Auditory tests were performed at least 1 year after cochlear implantation or upgrading the sound processor to ensure the best benefit of the implant. Auditory assessment of the implanted ear in free-field conditions included: pure-tone average (PTA), speech discrimination score (SDS) in quiet at 65 dB, and speech recognition threshold (SRT) in noise that is the SNR at which the patient can correctly recognize 50% of the words using the MT in a diffuse sound field. <b><i>Results:</i></b> The SRT in noise was determined in 60 patients (61%) and undetermined in 38 (39%) using the MT. When cut-off values for PTA &lt;36 dB and SDS &gt;41% were used separately, they were able to predict a positive response to the MT in 83% of recipients; using both cut-off values together, the predictive value reached 92%. <b><i>Discussion:</i></b> As the pure-tone audiometry is standardized universally and the speech recognition in quiet could vary depending on the language used; we propose that the MT should be performed in recipients with PTA &lt;36 dB, and in recipients with PTA &gt;36 dB, a list of Matrix sentences at a fixed SNR should be presented to determine the percentage of words understood. This approach should enable clinicians to obtain information about auditory performance in noise whenever possible.

Publisher

S. Karger AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3