Use of a Prophylactic Retrograde-Flushing Device in High-Risk Pediatric Patients with Ventriculoperitoneal Shunts: A Technical Note

Author:

Vinzani Michael,Alshareef Mohammed,Eskandari Ramin

Abstract

Introduction: Ventriculoperitoneal shunt (VPS) malfunction rates are as high as 40% in the first year with posthemorrhagic hydrocephalus (PHH) patients having the highest proximal occlusion risk. Debris, protein, and cellular ingrowth most commonly obstruct the proximal ventricular catheter and/or valve. Historically, no preventative methods have demonstrated efficacy. We present a technical note and case series describing the use of a retrograde proximal flushing device and prophylactic flushing protocol to maintain ventricular catheter patency and reduce proximal shunt occlusions. Methods: We present our 2.8–4-year follow-up data on the first 9 pediatric cases of ReFlow (Anuncia Inc, Scottsdale, AZ) device implantation combined with routine prophylactic flushing. Rationale for device implantation, patient selection, surgical procedure details, postoperative follow-up, and prophylactic flushing protocol are discussed as well as pre- and postimplantation ventricular catheter obstruction rates. We include a technical note on the device setup and prophylactic flushing protocol. Results: Patient average age was 5.6 years and all patients had PHH. Minimal follow-up was 2.8 years (range 2.8–4 years). Prophylactic flushing was initiated between 2 and 14 days after ReFlow implantation and has continued as of the last follow-up. In 7 patients, ReFlow implantation occurred during the revision of an existing shunt and in two, implantation was coincident with initial VPS placement. In the 2 years preceding ReFlow and prophylactic flushing, 14 proximal shunt failures occurred in the 7 patients with existing VPS. This was reduced to only one proximal shunt failure in all 9 patients during the full follow-up period after ReFlow and prophylactic flushing. Conclusion: Pediatric VPS placement carries high rates of proximal catheter occlusion, often leading to emergency surgery, morbidity, or even death. The ReFlow device along with routine prophylactic flushing may reduce proximal obstruction and need for revision surgery. Higher patient numbers and longer follow-up periods are necessary to further elucidate the safety and effect of such a device on longer term shunt failures and revision surgery.

Publisher

S. Karger AG

Subject

Neurology (clinical),General Medicine,Surgery,Pediatrics, Perinatology and Child Health

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3