Concurrent Validity of Inertially Sensed Measures during Voluntary Body Sway in Silence and while Exposed to a Rhythmic Acoustic Stimulus: A Pilot Study

Author:

Emmanouil Analina,Rousanoglou Elissavet,Georgaki Anastasia,Boudolos Konstantinos

Abstract

<b><i>Introduction:</i></b> The effect of rhythmic acoustic stimuli on body sway is of increasing interest due to their positive contribution when training or restoring the control of movement. Inertial sensors show promise as a portable, easier, and more affordable method compared to the force plate “gold standard” concerning the evaluation of postural sway. This study examined the concurrent validity of inertially sensed measures of voluntary body sway against those obtained with a force plate, in silence and while exposed to a rhythmic acoustic stimulus. <b><i>Methods:</i></b> Temporal (sway duration and variability) and spatial (trajectory length, variability, range, velocity, and area) body sway variables were extracted using an inertial sensor (at L5) in synchronization with a force plate, during anteroposterior body sway in silence and while exposed to a rhythmic acoustic stimulus (<i>n</i> = 18 young women; two 70-s trials in each condition). Statistics included bivariate correlations between the inertially sensed and the force plate measures, separately, in silence and with a rhythmic acoustic stimulus, as well as for the effect of the rhythmic acoustic stimulus (percentage difference from silence) (<i>p</i> ≤ 0.05, SPSS v25.0). <b><i>Results:</i></b> The inertially sensed measures demonstrated good-to-excellent concurrent validity for all temporal and almost all spatial variables, both in silence and with rhythmic acoustic stimulus (<i>r</i> &#x3e; 0.75, <i>p</i> = 0.000), as well as for the rhythmic acoustic-stimulus effect (<i>r</i> &#x3e; 0.75, <i>p</i> ≤ 0.05). <b><i>Conclusion:</i></b> The inertially sensed measures of the voluntary anteroposterior body sway demonstrated an overall good-to-excellent concurrent validity against those obtained with the force plate “gold standard,” both in the silence and the rhythmic acoustic stimulus conditions, as well as for the rhythmic acoustic-stimulus effect. The findings of this pilot study allow the recommendation of inertial sensing for the evaluation of postural control alterations when exposed to rhythmic acoustic stimuli, a condition of increasing interest due to the positive contribution of such stimuli when training or restoring the control of movement.

Publisher

S. Karger AG

Subject

General Engineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3