The Effect of Combined Phacoemulsification and Endo-Cyclophotocoagulation on Intraocular Pressure Fluctuation Assessed by the Water Drinking Test in Patients with Primary Open Angle Glaucoma

Author:

Mohammad Razali Amirah,Tang Seng Fai,Syed Zakaria Syed Zulkifli,Che-Hamzah Jemaima,Aung Tin,Othman Othmaliza,Md Din NorshamsiahORCID

Abstract

Introduction: The aim of this study was to assess the effect of phacoemulsification and endo-cyclophotocoagulation (phaco-ECP) on intraocular pressure (IOP) fluctuation as assessed by the water drinking test (WDT) in primary open angle glaucoma (POAG). Methods: This was a prospective observational study carried out at a tertiary referral centre. POAG patients on topical antiglaucoma medications and planned for phaco-ECP were recruited. WDT was performed before surgery and 6 weeks postoperatively by drinking 10 mL/kg of water in 5 min followed by serial IOP by Goldmann applanation tonometry measurements at 15, 30, 45, and 60 min. Mean IOP, IOP fluctuation (difference between highest and lowest IOP), IOP reduction, and factors affecting IOP fluctuation were analysed. Results: Twenty eyes from 17 patients were included. Baseline IOP was similar before (14.7 ± 2.7 mm Hg) and after (14.8 ± 3.4 mm Hg, p = 0.90) surgery. There was no difference in mean IOP (17.6 ± 3.4 mm Hg vs. 19.3 ± 4.7 mm Hg pre- and postoperative, respectively, p = 0.26) or peak IOP (19.37 ± 3.74 mm Hg vs. 21.23 ± 5.29 mm Hg, p = 0.25), albeit a significant reduction in IOP-lowering medications (2.2 ± 1.15 vs. 0.35 ± 0.93, p < 0.001) postoperatively. IOP fluctuation was significantly greater (6.4 ± 3.2 mm Hg vs. 4.6 ± 2.1 mm Hg, p = 0.015) with more eyes having significant IOP fluctuation of ≥6 mm Hg (11 eyes [55%] vs. 4 eyes [20%], p < 0.001) postoperatively. Factors that were significantly associated with increased postoperative IOP fluctuations were higher preoperative IOP fluctuation (β = 0.69, 95% CI 0.379–1.582, p = 0.004) and more number of postoperative antiglaucoma medications (β = 0.627, 95% CI 0.614–3.322, p = 0.008). Conclusion: Reducing aqueous production with phaco-ECP does not eliminate IOP fluctuation in POAG patients. The increase in postoperative IOP fluctuation suggests increased outflow resistance after phaco-ECP.

Publisher

S. Karger AG

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3