Abstract
Introduction: Although endocytoscopy (EC) with narrow-band imaging (NBI) is effective in diagnosing gastric cancer, no diagnostic system has been validated. We explored a specific diagnostic system for gastric cancer using EC with NBI. Methods: Equal numbers of images from cancerous and noncancerous areas (114 images each) were assessed by endoscopists with (development group: 33) and without (validation group: 28) specific training in magnifying endoscopy with NBI. Microvascular and microsurface patterns (MS) in each image were evaluated. Lesions were diagnosed as cancerous when patterns were deemed “irregular.” The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of a diagnosis according to patterns on EC with NBI (microvascular pattern [MV] alone, MS alone, and both) were evaluated and compared between groups to determine the diagnostic performance. Results: In the development and validation groups, diagnoses based on the MV alone had significantly higher accuracy (91.7% vs. 76.3%, p < 0.0001 and 92.5% vs. 67.5%, p < 0.0001, respectively) and sensitivity (88.6% vs. 68.3%, p < 0.0001 and 89.5% vs. 38.6%, p < 0.0001, respectively) than those based on the MS alone. In both groups, there were no significant differences in diagnostic accuracy between using the MV alone and both patterns. Discussion/Conclusion: Evaluation of the MV alone is a simple and accurate diagnostic method for gastric cancer. This system could find widespread applications in clinical practice.