Optical Quality Variation of Different Intraocular Lens Designs in a Model Eye: Lens Placed Correctly and in an Upside-Down Position

Author:

Lacort Marta,Pérez-Gracia JesúsORCID,Ares Jorge,Remón LauraORCID

Abstract

Introduction: Intraocular lenses (IOLs) may lose their optical quality if they are not correctly placed inside the capsular bag once implanted. One possible malpositioning of the IOL could be the implantation in an upside-down position. In this work, three aspheric IOLs with different spherical aberration (SA) have been designed and numerically tested to analyse the optical quality variation with the IOL flip, and misalignments, using a theoretical model eye. Methods: Using the commercial optical design software OSLO, the effect of decentration and tilt was evaluated by numerical ray tracing in two conditions: in their designed position and flipped with respect to the planned position (IOL is implanted upside down). The theoretical model eye used was the Atchison model eye. Seven IOL designs of +27.00 diopters were used: a lens with negative SA to correct the corneal SA, a lens to partially correct the corneal SA, and a lens to not add any SA to the cornea (aberration-free IOL). These lenses were designed with the aspherical surface located on the anterior and posterior IOL surface. A lens with no aspherical surfaces was also included. For the optical quality analysis, the modulation transfer function (MTF) was used, together with the Zernike wavefront aberration coefficients of defocus, astigmatism, and primary coma. Results: Off-centring and tilting the IOL reduced overall MTF values and increased wavefront aberration errors. With the IOL correctly positioned within the capsular bag, an aberration-free IOL is the best choice for maintaining optical quality. When the IOL is flipped inside the capsular bag, the optical quality changes, with the aberration-free IOL and the IOL without aspheric surfaces providing the worst results. With the lens in an upside-down position, an IOL design to partially correct corneal SA shows the best optical quality results in decentration and tilt, in terms of MTF and wavefront aberrations. Conclusion: The aberration-free IOL is the best choice when minimal postoperative errors of decentration or tilt are predicted. With IOL flip, the negative SA lens design is the best choice, regarding the root mean square wavefront aberrations. However, in a proper IOL implantation, the IOL designed to partially compensate the corneal SA including asphericity on its posterior surface is the better possible option, even in the presence of decentration or tilt.

Publisher

S. Karger AG

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3