Femtosecond LASER-Assisted Double Intraocular Lens Exchange in Nanophthalmic Eyes

Author:

Levinger Nadav,Erdinest Nir,London Naomi,Levinger Eliya,Goldfeather Ben Zaken Shalhevet,Barequet Dana,Barequet Irit,Achiron Asaf,Levinger Shmuel

Abstract

Introduction: Though patients with nanophthalmos frequently endure decreased quality of vision with contact lenses or spectacles, refractive surgery is generally an inadequate alternative due to the associated high refractive error. A refractive lens exchange (RLE) is an alternative option but is technically challenging, requiring accuracy in biometry measurements and procedures. Case Presentation: This case discusses a 27-year-old female with nanophthalmos (axial lengths 17.6 mm and 17.4 mm, right and left eyes, respectively) who underwent a femtosecond laser-assisted (FLA) RLE with simultaneous implantation of a monofocal and a Sulcoflex trifocal (Rayner, Britain) lens in each eye. Preoperative cycloplegic refraction was +11.50/−0.75 × 145 and +12.00/−1.00 × 35 in the RE and LE, respectively. Best-corrected visual acuity (BCVA) at distance and near in the RE and LE was 6/7.5 and J1, 6/8.5 and J2, respectively. Uncorrected visual acuity (UCVA) was >6/120 and >J14 for each eye. FLA RLE was performed in the RE, then in the LE 2 weeks later. In each eye, a monofocal (44.0 D, RE, and LE) and a Sulcoflex trifocal lens (both implants, Rayner, Britain) were implanted in one procedure. Distance and near UCVA measured 6 weeks post-op RE and 1-month post-op LE at 6/8.5 and J1 in the RE, 6/10 and J1 in the LE. The RE and LE refraction and BCVA were +0.50/−1.00 × 115, 6/7.5, and plano/−1.00 × 55, 6/8.5, respectively. The post-op outcomes were uneventful. Conclusion: A single procedure concurrently implanting a monofocal and Sulcoflex trifocal intraocular lens in nanophthalmic eyes resulted in an excellent UCVA. This procedure can be considered esthetic and reconstructive as it significantly improves patient appearance and function.

Publisher

S. Karger AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Erratum;Case Reports in Ophthalmology;2024-02-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3