Thrombectomy Outcomes in Acute Ischemic Stroke due to Middle Cerebral Artery M2 Occlusion with Stent Retriever versus Aspiration: A Multicenter Experience

Author:

Atchaneeyasakul Kunakorn,Malik Amer M.,Yavagal Dileep R.,Haussen Diogo C.,Jadhav Ashutosh P.,Bouslama MehdiORCID,Kenmuir Cynthia L.,Desai Shashvat,Grossberg Jonathan A.,Chaturvedi Seemant,Jovin Tudor G.,Nogueira Raul G.

Abstract

Objective: To examine outcomes for thrombectomy devices used for treatment of acute ischemic stroke (AIS) with middle cerebral artery (MCA) M2 segment emergent large vessel occlusion (ELVO) as the optimal device for such reperfusion is not clearly defined. Methods: A retrospective cohort study of consecutive AIS patients with MCA M2 ELVO undergoing thrombectomy from 3 academic medical centers was conducted from October 1999 through June 2016. The patients were divided based on the device utilized. Multivariate analysis of associations between devices (stent retriever or aspiration only [manual or pump aspiration system]) was performed. Primary outcomes were good recanalization (i.e., modified thrombolysis in cerebral infarction score ≥2b) and a favorable modified Rankin scale (mRS) score (i.e. ≤2). The secondary outcome was symptomatic intracerebral hemorrhage (sICH). Results: A total of 197 AIS patients underwent MCA M2 ELVO thrombectomy with either a stent retriever (n = 120) or aspiration only (n = 77). The aspiration-only group utilized either manual (n = 38) or pump aspiration (n = 39). Utilization of a stent retriever over manual aspiration is independently associated with higher odds of a favorable mRS score (OR = 3.2; 95% CI 1.02–9.7) and lower odds of sICH (OR = 0.09; 95% CI 0.03–0.31). Utilization of a stent retriever over a pump aspiration system is independently associated with higher odds of good recanalization (OR = 3.8; 95% CI 1.5–9.6). Utilization of a newer-generation pump aspiration catheter compared to a stent retriever resulted in similar rates of favorable mRS scores, sICH, successful recanalization, and mortality. Conclusion: Utilization of a newer-generation pump aspiration catheter compared to a stent retriever resulted in similar outcomes, but worse outcomes were seen with the manual aspiration technique. These findings need to be confirmed with a large randomized trial utilizing stent retrievers and newer-generation pump aspiration systems.

Publisher

S. Karger AG

Subject

Cardiology and Cardiovascular Medicine,Clinical Neurology,Surgery

Reference7 articles.

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3