Comparison of Aurolab Aqueous Drainage Implant with Ahmed Glaucoma Valve for Refractory Glaucoma: A Meta-Analysis

Author:

Hong Mingsheng,Peng Yaling,Lai Yuan,Zheng Qingqing,Hong ChaoyangORCID

Abstract

Background: Ahmed glaucoma valve (AGV) is a common surgical method for the treatment of refractory glaucoma.Aurolab aqueous drainage implant (AADI) is a novel surgical method which has been applied in clinical practice in recent years. Objective: The purpose of this study was to compare the efficacy and safety of the AADI and the AGV for the treatment of refractory glaucoma. Methods: We comprehensively searched four databases, including PubMed, Embase, Web of Science, and the Cochrane Library databases, selecting the relevant studies. The continuous variables, namely, intraocular pressure reduction (IOPR) and a reduction in antiglaucoma medication (AGMR), were pooled by the weighted mean differences (WMDs), and the dichotomous outcomes, including success rates and complications, were pooled by the odds ratio (OR). Results: A total of 825 eyes from 820 patients from six studies were included. The WMDs of the IOPR between the AADI and the AGV implant were 0.58 (95% CI: 0.07–1.09) at 3 months, 0.44 (95% CI: 0.11–0.77) at 6 months, 2.20 (95% CI: 0.63–3.77) at 12 months, and 3.24 (95% CI: 1.73–4.75) at follow-up endpoint. Significant difference was detected between the two groups at any point in time. The WMDs of the AGMR between the AADI and the AGV implant were 0.87 (95% CI: 0.61–1.13) at 6 months, 1.04 (95% CI: 0.66–1.42) at 12 months, and 0.93 (95% CI: 0.52–1.34) at the follow-up endpoint; the differences reached statistical significance at any point in time. The pooled ORs comparing the AADI with the AGV were 3.64 (95% CI: 2.44–5.45) for the complete success rate and 1.72 (95% CI: 1.24–2.39) for qualified success rate; significant difference was detected between the two groups. There were no significant differences between the AADI and the AGV implant on the rates of adverse events. Conclusions: The AADI is more effective in both its surgical success rate and reducing IOP and AGM. And the two implants may have comparable incidences of adverse events.

Publisher

S. Karger AG

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3