Cochlear Implantation with the CI512 and CI532 Precurved Electrode Arrays: One-Year Speech Recognition and Intraoperative Thresholds of Electrically Evoked Compound Action Potentials

Author:

Videhult Pierre PernillaORCID,Eklöf Martin,Smeds Henrik,Asp Filip

Abstract

Introduction: Precurved cochlear implant (CI) electrode arrays were developed in an attempt to improve the auditory outcome of cochlear implantation, which varies greatly. The recent CI532 (Cochlear Corp., Sydney, Australia) may offer further advantages as its electrode array is thinner than previous precurved CI electrode arrays. The aims here were to investigate 1-year postoperative speech recognition, intraoperative electrically evoked compound action potentials (ECAPs), and their possible relation in patients implanted with a CI532 or its predecessor CI512. Methods: A retrospective analysis of data from 63 patients subjected to cochlear implantation at the Karolinska University Hospital, Sweden, was performed. Speech recognition of the implanted ear was evaluated using phonemically balanced monosyllabic Swedish words at 65 dB SPL. ECAPs were evaluated using the intraoperative ECAP threshold across ≥8 electrodes generated by the automated neural response telemetry of the CI. Results: The median aided speech recognition score (SRS) 1 year after implantation was 52% (quartile 1 = 40%, quartile 3 = 60%, n = 63) and did not differ statistically significantly between patients with CI512 (n = 38) and CI532 (n = 25). The mean ECAP threshold was 188 CL (current level; SD = 15 CL, n = 54) intraoperatively and did not differ statistically significantly between patients with CI512 (n = 32) and CI532 (n = 22), but the threshold for each electrode varied more between patients with a CI512 (p < 0.0001). A higher mean ECAP threshold was associated with a worse SRS (Spearman’s ρ = –0.46, p = 0.0004, n = 54). The association remained among those with a CI512 (Spearman’s ρ = –0.62, p = 0.0001, n = 32) when stratified by CI electrode array. Conclusion: No statistically significant difference in speech recognition 1 year after cochlear implantation or in mean threshold of ECAP intraoperatively was found between patients with a CI512 and the more recent, slim CI532, but the ECAP thresholds varied more between those with a CI512. A statistically significant association between SRS and mean ECAP threshold was found, but stratified analysis suggests that the association may be true only for patients with a CI512.

Publisher

S. Karger AG

Subject

Speech and Hearing,Sensory Systems,Otorhinolaryngology,Physiology

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3