Development of preanalytical criteria assessment of quality of vacuum blood collection systems affecting clinical examination of patients

Author:

Kazakov S. P.1ORCID,Suslova L. A.2ORCID

Affiliation:

1. N. Burdenko Main Military Clinical Hospital; Russian Medical Academy of Continuing Professional Education

2. N. Burdenko Main Military Clinical Hospital

Abstract

This paper presents comparative studies of preanalytical quality indices of vacuum gel systems (VGS) from four manufacturers, i.e., GL 795 (China), Vacuette (Austria), BD Vacutainer SST (USA) and Zdravmedtech (Russia). The analysis of the number of qualitative defects of the preanalytic phase of blood collection in vacuum gel tubes at the inpatient departments and in Department of Clinical Chemistry (preanalytic laboratory), in accordance with adopted criteria based on Russian industry standards, which are implemented with European indices of pre-analytic stage. The obtained results allowed us to identify a number of qualitative defects at pre-analytic stage for the vacuum gel systems from each manufacturer, including to summarize the data on number of these defects. Based on these results, the most common defects in each of the VGS presented by manufacturers are formulated. The results obtained can be used by manufacturers to improve the quality (structures) of the mentioned vacuum gel tubes.The results of the comparative characteristics of VGS of different manufacturers were evaluated by their influence on the indexes of hemolysis (IH), ictericity, lipemia. The resulting indices of ictericity and lipemia do not allow to use them as criteria for assessing quality of the gel systems. The frequency of IH occurrence in serum at > 50 conventional units in VGS of different manufacturers was studied. It was revealed, that IH in the range from 10 to 50 conventional units and more, can be used as a criterion of VGS quality.Comparison of routine biochemical parameters in VGS of different manufacturers, i.e., alanine aminotransferase, aspartate aminotransferase, direct bilirubin, lactate dehydrogenase (LDH), serum K+, was also carried out. It was found that the largest deviations from the average value were obtained for aspartate aminotransferase indices of more than 12.47% in Russian test tubes, and for direct bilirubin of more than 12.25% in Chinese test tubes and more than 9.15% in Russian test tubes. The study showed influence of IH upon quantitative values of lactate dehydrogenase for VGS from different manufacturers. It is proposed to use lactate dehydrogenase as an analyte. On this basis, it is possible to recommend a comparative quality assessment of vacuum gel systems, with IH cutoff level of more than 19 conventional units. It remains relevant to search for other analytes that can be used to assess the quality of VGS from different manufacturers. Some areas of research in biochemical testing are outlined. Preliminary data are obtained on usage of vacuum systems from different manufacturers for quality assessment, as well as conditions for performing these tests, along with the level of the hemolysis index of more than 10 conventional units.

Publisher

SPb RAACI

Subject

Immunology,Immunology and Allergy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Design of automatic blood collection scale system and study on measurement method of blood collection velocity;2023 2nd International Conference on Health Big Data and Intelligent Healthcare (ICHIH);2023-10-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3