Video-Assisted Thoracoscopic Surgery for Patent Ductus Arteriosus in Low Birth Weight Neonates and Infants

Author:

Burke Redmond P.1,Jacobs Jeffrey P.2,Cheng Wen3,Trento Alfredo3,Fontana Gregory P.3

Affiliation:

1. From the Division of Cardiovascular Surgery, Miami Children's Hospital, Miami, Florida;

2. Division of Thoracic and Cardiovascular Surgery, All Children's Hospital, University of South Florida College of Medicine, St Petersburg, Florida; and

3. Division of Cardiovascular Surgery, Cedars Sinai Hospital, Los Angeles, California.

Abstract

Background. Video-assisted thoracoscopic surgery (VATS) has been assuming an expanded role in the management of cardiothoracic disease. As instrumentation and experience increase, VATS is being applied to treat smaller patients. We report our experience with 34 low birth weight infants undergoing VATS interruption of patent ductus arteriosus (PDA). Methods. VATS allows PDA interruption without the muscle cutting or rib spreading of a standard thoracotomy. Four small, 3-mm incisions are made along the line of a potential thoracotomy incision. Ports placed through these incisions admit endoscopic instruments, a camera, and a vascular clip applier. Results. Median age at surgery was 15.5 days (range: 1–44 days). Median weight at surgery was 930 g (range: 575-2500 g). Twenty patients weighed <1 kg, and 13 weighed <750 g. All patients had congestive heart failure and had either failed indomethacin therapy or had contraindications to indomethacin. Median surgical time was 60 minutes (range: 31–171 minutes). Echocardiography documented elimination of ductal flow in all patients. Operative mortality was zero. Four patients (4/34 = 12%) required conversion to open thoracotomy: 1 because of difficult exposure, 1 because of pulmonary dysfunction and anasarca, 1 because of a large 1-cm duct, and 1 because of coagulopathy and poor pulmonary compliance. Two patients died before discharge: 1 patient (surgical weight: 605 g) died on postoperative day 2 because of intracranial hemorrhage, and 1 patient (surgical weight: 1725 g) died on postoperative day 88 because of multiple system organ failure. Follow-up has demonstrated no PDA murmur in any patient, but echocardiography revealed trace ductal flow in 2 patients. Conclusions. VATS offers a minimally traumatic, safe, and effective technique for PDA interruption in low birth weight neonates and infants.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology, and Child Health

Cited by 80 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3