Comparison Between Simultaneously Recorded Amplitude Integrated Electroencephalogram (Cerebral Function Monitor) and Standard Electroencephalogram in Neonates

Author:

Toet Mona C.1,van der Meij Wil2,de Vries Linda S.1,Uiterwaal Cuno S. P. M.3,van Huffelen Kees C.2

Affiliation:

1. Department of Neonatology, Utrecht, the Netherlands

2. Department of Clinical Neurophysiology, Utrecht, the Netherlands

3. Julius Center for Patient Oriented Research, Utrecht, the Netherlands

Abstract

Objective: To assess the value and the limitations of amplitude integrated electroencephalogram (EEG) using the cerebral function monitor (CFM) in comparison with standard EEG in neonates who have hypoxic ischemic encephalopathy or were suspected of having convulsions. Methods. In 36 neonates with a gestational age ≥36 weeks, CFM and simultaneously recorded EEG traces were analyzed off-line and independently classified. CFM background activity: continuous normal voltage; continuous normal voltage, slightly discontinuous (DNV); burst-suppression (BS); continuous extremely low voltage; flat tracing. CFM epileptiform activity: suspected epileptic activity, single seizure (SS), repetitive seizures (RS), status epilepticus (SE). EEG background activity: normal, depressed, low voltage undifferentiated, excessive discontinuity, BS, no activity. Epileptiform activity: interictal unifocal, interictal multifocal, ictal unifocal, ictal multifocal, SE. Results. A total of 33 traces were suitable for analysis. Interobserver agreement on background activity was reached in 31 cases (κ = 0.92) for CFM and in 27 cases (κ = 0.74) for EEG. There was full agreement on CFM ictal activity (RS, SS, or SE) and EEG ictal activity. A normal CFM (continuous normal voltage) corresponded with a normal or a depressed EEG in 90% of the cases. The positive predictive value for a severely abnormal CFM (BS, continuous extremely low voltage, flat tracing) to correspond with a severely abnormal EEG (excessive discontinuity, BS, low voltage undifferentiated, no activity) was 100% (negative predictive value, 80%; sensitivity, 76%; specificity, 100%). DNV (10) on CFM corresponded either with depressed (6) or excessive discontinuity (4) on EEG. Ictal activity on EEG corresponded with SS, RS, or SE on CFM in 8 cases (sensitivity, 80%; specificity, 100%; positive predictive value, 100%; negative predictive value, 92%). Conclusion. CFM is a reliable tool for monitoring both background patterns (especially normal and severely abnormal) and ictal activity. Certain focal, low amplitude, and very short periods of seizure discharges can be missed. We recommend using CFM as a monitoring device and performing intermittent standard EEG whenever there is any doubt about the classification of the CFM (ie, DNV pattern or suspected epileptiform activity).

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

Cited by 258 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3