Effect of Flow Rate and Insulin Priming on the Recovery of Insulin From Microbore Infusion Tubing

Author:

Fuloria Mamta1,Friedberg Michael A.2,DuRant Robert H.1,Aschner Judy L.1

Affiliation:

1. From the Department of Pediatrics and Brenner Center for Child and Adolescent Health, and the

2. Department of Pathology, Wake Forest University School of Medicine, Winston-Salem, North Carolina.

Abstract

Background. A retrospective medical record review of 13 consecutive, hyperglycemic, extremely low birth weight (ELBW) infants treated with continuous insulin infusions revealed a 14- to 24-hour delay (mean, 19 hours) in blood glucose normalization despite stepwise increases in insulin infusion rates. Objective. This in vitro study examined the effects of flow rate and insulin priming on insulin recovery from polyvinyl chloride (PVC) tubing and polyethylene (PE)-lined PVC tubing infused with a standard insulin stock solution. Methods. Stock insulin solution (0.2 U/mL) was infused through microbore PVC or PE-lined tubing at flow rates of 0.05 and 0.2 mL/h. To determine if saturation of nonspecific binding sites would alter effluent insulin concentration, we compared insulin recovery from tubing previously flushed with the stock solution and tubing primed with 5 U/mL of insulin for 20 minutes. Effluent samples, which were collected at baseline and at six time points during a 24-hour period, were immediately frozen at −20°C. Insulin concentration was measured by IMx immunoassay. Data were analyzed using general linear modeling with repeated measures. Results. At 0.05 mL/h flow rate, insulin recovery from unprimed PVC tubing at 1, 2, 4, and 8 hours was 17%, 11%, 27%, and 55%, respectively, with 100% recovery at 24 hours. From insulin-primed tubing, insulin recovery was ∼70% at 1, 2, and 4 hours, and close to 100% at 8 hours. At a faster flow rate of 0.2 mL/h, insulin recovery at 1, 2, 4, and 8 hours was 22%, 38%, 67%, and 75% vs 42%, 85%, 91% and 95% from unprimed and insulin-primed PVC tubing, respectively. Similar results were obtained from unprimed and insulin-primed PE-lined tubing at 0.2 mL/h flow rate. Conclusions. Priming of microbore tubing with 5 U/mL of insulin solution for 20 minutes to block nonspecific binding sites enhances delivery of a standard insulin stock at infusion rates typically used to treat hyperglycemic ELBW infants. We conclude that priming the tubing with a higher concentration of insulin before initiation of standard insulin infusion therapy should accelerate achievement of steady-state insulin delivery and correction of hyperglycemia in ELBW infants.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

Reference15 articles.

1. Risk factors for neonatal hyperglycemia associated with 10% dextrose infusion.;Louik;Am J Dis Child,1985

2. Glucose intolerance in infants of very low birth weight. I. Incidence of hyperglycemia in infants of birth weight 1100 grams or less.;Dweck;Pediatrics,1974

3. Glucose disposal in low-birth weight infants during steady-state hyperglycemia: effects of exogenous insulin administration.;Pollak;Pediatrics,1978

4. Continuous insulin infusion in hyperglycemic, very low birth weight infants.;Vaucher;J Pediatr Gastroenterol Nutr,1982

5. Insulin pump therapy in the very low birth weight infant.;Ostertag;Pediatrics,1986

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3