A Prospective Comparison of Diaphragmatic Ultrasound and Chest Radiography to Determine Endotracheal Tube Position in a Pediatric Emergency Department

Author:

Kerrey Benjamin Thomas12,Geis Gary Lee12,Quinn Andrea Megan1,Hornung Richard William3,Ruddy Richard Michael12

Affiliation:

1. Divisions of Emergency Medicine

2. College of Medicine, University of Cincinnati, Cincinnati, Ohio

3. General and Community Pediatrics, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio

Abstract

BACKGROUND. Investigators report endotracheal tube misplacement in up to 40% of emergent intubations. The standard elements of confirmation have significant limitations. Diaphragmatic ultrasound is a potentially viable addition to the confirmatory process. Our primary hypothesis is that ultrasound is equivalent to chest radiography in determining endotracheal tube position within the airway in emergent pediatric intubations. METHODS. We enrolled a prospective, convenience sample from all intubated patients in our emergency department. The primary outcome was the agreement between diaphragmatic ultrasound and chest radiography for endotracheal tube position. On ultrasound, tracheal placement equaled bilateral diaphragmatic motion, bronchial placement equaled unilateral diaphragmatic motion, and esophageal placement equaled no or paradoxical diaphragmatic motion during delivery of positive pressure. Study sonographers were blind to radiographic results. Our secondary outcome was the timeliness of ultrasound versus chest radiography results. Our institutional review board approved this study with a waiver of informed consent. RESULTS. One hundred twenty-seven patients were enrolled. In 24 (19%) patients, the endotracheal tube was in the mainstem bronchus on chest radiography. There were no esophageal intubations in the sample. Ultrasound and chest radiography agreed on endotracheal tube placement in 106 patients (94 tracheal and 12 mainstem), for an overall agreement of 0.83. The sensitivity of ultrasound for tracheal placement was 0.91. The specificity of ultrasound for mainstem intubation was 0.50. Thirty-four patients had a second ultrasound by a separate, blinded sonographer; 33 of 34 of the results of the second sonographer were in agreement with the initial sonogram, for an interrater agreement of 97%. Clinically useful chest radiography results took a median of 8 minutes longer to achieve than ultrasound results. CONCLUSIONS. Diaphragmatic ultrasound was not equivalent to chest radiography for endotracheal tube placement within the airway. However, ultrasound results were timelier, detected more misplacements than standard confirmation alone, and were highly reproducible between sonographers.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

Cited by 104 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3