Affiliation:
1. Clinic of Neonatology Charité Campus Mitte
2. Institute of Radiology
3. Department of Pediatric Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
Abstract
OBJECTIVE: We determined the frequency and estimated effective radiation dose (E) from conventional diagnostic radiographs for infants who had birth weight of ≤1500 g (very low birth weight [VLBW] infants) and were treated in a NICU.
METHODS: Entrance skin doses were experimentally measured for all standard weight-dependent exposure settings. For each radiograph in the radiologic file, the exposed area on the film was measured manually. Together with clinical data obtained from the Vermont Oxford Network, medical charts, and radiologic files, we estimated E. E values per radiograph and per child were compared with recommended reference values and annual natural background radiation (NBR). We used reference data to estimate the risk for radiation-induced cancers.
RESULTS: Of 212 VLBW infants, 194 required at least 1 conventional radiograph. Measured entrance skin dose varied between 11.8 and 15.0 μGy. Calculated E received was 16 microsievert (μSv; median) per radiograph and 71.5 μSv (median) per infant for the whole stay. Infants with birth weight ≤750 g, length of stay ≥16 weeks, congenital malformations, or oxygen dependence for ≥36 weeks were at risk for high numbers of radiographs and high radiation dose. Compared with the annual NBR, the median of 4 radiographs per infant contributes 12 days of NBR. We estimated that only 1 of 60000 NICU-treated VLBW infants will develop a fatal malignancy up to 15 years of age.
CONCLUSIONS: We found that NICU-treated VLBW infants had low radiation exposure compared with the annual NBR.
Publisher
American Academy of Pediatrics (AAP)
Subject
Pediatrics, Perinatology and Child Health
Reference40 articles.
1. United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and effects of ionizing radiation. UNSCEAR 2000 Report to the General Assembly. Available at: www.unscear.org/unscear/en/publications/2000_1.html. Accessed October 10, 2008
2. Almen AJ, Mattsson S. On the calculation of effective dose to children and adolescents. J Radiol Prot. 1996;16(2):81–89
3. Martin JA, Hsiang-Ching K, Martin JA, et al. Annual summary of vital statistics: 2006. Pediatrics. 2008;121(4):788–801
4. International Commission on Radiological Protection. 1990 Recommendations of the International Commission on Radiological Protection. Oxford, England: Pergamon Press; 1991. ICRP Publication No 60
5. McCollough CH, Schueler BA. Calculation of effective dose. Med Phys. 2000;27(5):828–837
Cited by
65 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献