A Survey of Delivery Room Resuscitation Practices in the United States

Author:

Leone Tina A.1,Rich Wade1,Finer Neil N.1

Affiliation:

1. Department of Pediatrics, Division of Neonatology, University of California, San Diego, San Diego, California

Abstract

Objective. To determine current resuscitation practices of neonatologists in the United States. METHODS. A 15-question survey was developed and mailed to neonatal directors in May 2004. ELRESULTS. Of the total of 797 surveys mailed, 84 were returned undeliverable or unanswered and 450 were returned completed (63% response rate). Respondents were mainly (70%) from level III NICUs. Most programs resuscitate newborns in the delivery room (83%), rather than in a separate room. The number and background of individuals attending deliveries vary greatly, with 31% of programs having <3 individuals attending deliveries. Flow-inflating bags are most commonly used (51%), followed by self-inflating bags (40%) and T-piece resuscitators (14%). Pulse oximeters are used during resuscitation by 52% of programs, and 23% of respondents indicated that there was a useful signal within 1 minute after application. Blenders are available for 42% of programs, of which 77% use pure oxygen for the initial resuscitation and 68% use oximeters to alter the fraction of inspired oxygen. Thirty-two percent of programs use carbon dioxide detectors to confirm intubation, 48% routinely and 43% when there is difficulty confirming intubation. Preterm infants are wrapped with plastic wrap to prevent heat loss in 29% of programs, of which 77% dry the infant before wrap application. A majority of programs (76%) attempt to provide continuous positive airway pressure or positive end expiratory pressure (PEEP) during resuscitation, most commonly with a flow-inflating bag (58%), followed by a self-inflating bag with PEEP valve (19%) and T-piece resuscitator (16%). A level of 5 cm H2O is used by 55% of programs. CONCLUSIONS. Substantial variations exist in neonatal resuscitation practices, some of which are not addressed in standard guidelines. Future guidelines should include recommendations regarding the use of blenders, oximeters, continuous positive airway pressure/PEEP, and plastic wrap during resuscitation.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

Reference26 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3