Office Spirometry in Primary Care Pediatrics: A Pilot Study

Author:

Zanconato Stefania1,Meneghelli Giorgio2,Braga Raffaele3,Zacchello Franco1,Baraldi Eugenio1,

Affiliation:

1. Department of Pediatrics, University of Padova, Padova, Italy

2. Primary Care Pediatrics, Federazione Italiana Medici Pediatri, Italy

3. Valeas SpA, Milano, Italy

Abstract

Objective. The aim of this study was to investigate the validity of office spirometry in primary care pediatric practices. Methods. Ten primary care pediatricians undertook a spirometry training program that was led by 2 pediatric pulmonologists from the Pediatric Department of the University of Padova. After the pediatricians' training, children with asthma or persistent cough underwent a spirometric test in the pediatrician's office and at a pulmonary function (PF) laboratory, in the same day in random order. Both spirometric tests were performed with a portable turbine flow sensor spirometer. We assessed the quality of the spirometric tests and compared a range of PF parameters obtained in the pediatricians' offices and in the PF laboratory according to the Bland and Altman method. Results. A total of 109 children (mean age: 10.4 years; range: 6–15) were included in the study. Eighty-five (78%) of the spirometric tests that were performed in the pediatricians' offices met all of the acceptability and reproducibility criteria. The 24 unacceptable test results were attributable largely to a slow start and failure to satisfy end-of-test criteria. Only the 85 acceptable spirometric tests were considered for analysis. The agreement between the spirometric tests that were performed in the pediatrician's office and in the PF laboratory was good for the key parameters (forced vital capacity, forced expiratory volume in 1 second, and forced expiratory flow between 25% and 75%). The repeatability coefficient was 0.26 L for forced expiratory volume in 1 second (83 of 85 values fall within this range), 0.30 L for forced vital capacity (81 values fall within this range), and 0.58 L/s for forced expiratory flow between 25% and 75% (82 values fall within this range). In 79% of cases, the primary care pediatricians interpreted the spirometric tests correctly. Conclusions. It seems justifiable to perform spirometry in pediatric primary care, but an integrated approach involving both the primary care pediatrician and certified pediatric respiratory medicine centers is recommended because effective training and quality assurance are vital prerequisites for successful spirometry.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3