Affiliation:
1. Unit of Toxicology, Department of Public Health, Faculty of Medicine, Catholic University of Louvain, Brussels, Belgium
Abstract
OBJECTIVE. Irritant gases and aerosols contaminating the air of indoor swimming pools can affect the lung epithelium and increase asthma risk in children. We evaluated the impact of infant swimming practice on allergic status and respiratory health later in childhood.
METHODS. Clara cell protein, surfactant-associated protein D, and total and aeroallergen-specific immunoglobulin E were measured in the serum of 341 schoolchildren aged 10 to 13 years, among whom 43 had followed an infant swimming program. Asthma was defined as doctor-diagnosed asthma and/or positive exercise-induced bronchoconstriction (15% decrease in postexercise forced expiratory volume).
RESULTS. There were no significant differences between the infant swimming group and the other children regarding the levels of exhaled nitric oxide and total or aeroallergen-specific serum immunoglobulin E. Children who swam as infants showed, by contrast, a significant decrease of serum Clara cell protein and of the serum Clara cell protein/surfactant-associated protein D ratio integrating Clara cell damage and permeability changes of the lung epithelial barrier. These effects were associated with higher risks of asthma and of recurrent bronchitis. Passive exposure to tobacco alone had no effect on these outcomes but seemed to interact with infant swimming practice to increase the risk of asthma or of recurrent bronchitis.
CONCLUSIONS. Our data suggest that infant swimming practice in chlorinated indoor swimming pools is associated with airways changes that, along with other factors, seem to predispose children to the development of asthma and recurrent bronchitis.
Publisher
American Academy of Pediatrics (AAP)
Subject
Pediatrics, Perinatology, and Child Health
Reference44 articles.
1. Jessen HJ. Chloramine concentrations in the air of indoor baths [in German]. Z Gesamte Hyg. 1988;34:248–250
2. Hery M, Hecht G, Gerber JM, Gendre J, Hubert G, Rebuffaud J. Exposure to chloramines in the atmosphere of indoor swimming pools. Ann Occup Hyg. 1995;39:427–439
3. Fraunhofer Institute Umwelt, Sicherheit, Energietechniek (IUSE). Measuring Chloramines in the Air of Swimming Pools. Stolberg, Germany: IUSE; 2004
4. Agibati N, Ancona C, Forastiere F, et al. Short term respiratory effects of acute exposure to chlorine due to swimming pool accident. Occup Environ Med. 2001;58:399–404
5. Parimon T, Kanne JP, Pierson DJ. Acute inhalation injury with evidence of diffuse bronchiolitis following chlorine gas exposure at a swimming pool. Respir Care. 2004;49:291–294
Cited by
119 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献