Extent of Agreement in Gentamicin Concentration Between Serum That Is Drawn Peripherally and From Central Venous Catheters

Author:

Boodhan Sabrina1,Maloney Anne Marie23,Dupuis L. Lee1345

Affiliation:

1. Departments of Pharmacy

2. Nursing

3. Division of Haematology/Oncology

4. Population Health Sciences, Research Institute, Hospital for Sick Children

5. Faculty of Pharmacy, University of Toronto, Toronto, Ontario, Canada

Abstract

OBJECTIVE. At our institution, patients who receive once-daily dosing of gentamicin have serum concentrations determined 3 and 6 hours after dose administration. Patients with single-lumen central venous catheters have the 3-hour samples drawn peripherally. The objective of this study was to evaluate the extent of agreement between peripheral and central venous catheter serum gentamicin concentrations drawn 3 hours after dose administration. METHODS. In this prospective, observational study, patients provided both a peripheral and a central blood sample for determination of serum gentamicin concentration. The order of sampling (central venous catheter versus peripheral first) was randomized. Agreement was assessed by determination of the intraclass correlation coefficient and Bland-Altman analysis. The clinically acceptable targets for the lower limit of the intraclass correlation coefficient and Bland-Altman limits of agreement were defined a priori as >0.80 and ±6%, respectively. Differences between the theoretical dose adjustments using the central venous catheter versus the peripheral sample result were described. RESULTS. Forty-five pairs of samples were collected: 42 from single-lumen implantable central venous catheters (ports) and 3 from peripherally inserted central venous catheters. The intraclass correlation coefficient was 0.91. However, the Bland-Altman analysis resulted in a mean percentage difference (central venous catheter versus peripheral) of −0.92% and limits of agreement of −27.9% to 26.0%. The gentamicin dose adjustment based on the central venous catheter sample result would have led to clinically significant dose adjustments in 19 (42%) cases, when compared with the peripheral sample result. CONCLUSIONS. These results indicate a lack of agreement between peripheral and single-lumen central venous catheter samples. In particular, ports are not appropriate sites for monitoring serum gentamicin concentrations.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3