Hemodynamic Changes During Weaning From Nasal Continuous Positive Airway Pressure

Author:

Abdel-Hady Hesham1,Matter Mohamed2,Hammad Ayman1,El-Refaay Ahmed1,Aly Hany3

Affiliation:

1. Neonatal Care Unit

2. Pediatric Cardiology Unit, Mansoura University Children's Hospital, Egypt

3. Department of Neonatology, The George Washington University and the Children's National Medical Center, Washington, DC

Abstract

BACKGROUND. Nasal continuous positive airway pressure is frequently used to support preterm infants with respiratory distress syndrome. Little is known about the hemodynamic changes that occur, particularly during the weaning phase when lung compliance has improved and most of the airway pressure can be transmitted to the heart and major blood vessels. METHODS. We conducted a prospective study on preterm infants (gestational age ≤32 weeks) with resolving respiratory distress syndrome, who were receiving nasal continuous positive airway pressure of 5 cm H2O and 21% oxygen. While cycling nasal continuous positive airway pressure, we performed 2-dimensional M-mode and pulsed Doppler echocardiography on all infants during nasal continuous positive airway pressure and 1 hour after being off nasal continuous positive airway pressure. RESULTS. A total of 25 preterm infant were studied. The use of nasal continuous positive airway pressure significantly decreased right ventricular output (320 ± 22.7 vs 410.5 ± 44.1 mL/kg per min); right ventricular end diastolic diameter (6 ± 0.7 vs 6.4 ± 0.4 mm), left ventricular end diastolic diameter (11.6 ± 0.9 vs 13.6 ± 0.7 mm), left ventricular end systolic diameter (7.1 ± 0.6 vs 8.3 ± 0.4 mm), left atrial diameter (6.3 ± 0.5 vs 8 ± 0.5 mm), aortic root diameter (6.4 ± 0.3 vs 6.6 ± 0.4 mm), superior vena cava flow (70.2 ± 8.5 vs 91.1 ± 4 mL/kg per minute), and pulmonary maximum velocity (0.6 ± 0.1 vs 0.7 ± 0.1 m/seconds). It significantly increased mean inferior vena cava diameter (4.3 ± 0.5 vs 3.5 ± 0.6 mm), whereas nasal continuous positive airway pressure did not influence left ventricular output, aortic maximum velocity, fractional shortening, heart rate, or mean arterial blood pressure. Changes associated with nasal continuous positive airway pressure were similar in infants with (n = 8) and without (n = 17) patent ductus arteriosus. CONCLUSIONS. In infants with resolving respiratory distress syndrome, nasal continuous positive airway pressure can impede systemic and pulmonary venous return, but it does not compromise systemic arterial pressure or heart rate. It is not clear whether the degree of these hemodynamic changes can affect the success of weaning off nasal continuous positive airway pressure.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3