Measurement of Percentage of Body Fat in 411 Children and Adolescents: A Comparison of Dual-Energy X-Ray Absorptiometry With a Four-Compartment Model

Author:

Sopher Aviva B.12,Thornton John C.2,Wang Jack2,Pierson Richard N.2,Heymsfield Steven B.12,Horlick Mary23

Affiliation:

1. Institute of Human Nutrition, Columbia University, New York, New York

2. Body Composition Unit of St Luke’s-Roosevelt Hospital Center, Columbia University, New York, New York

3. Children’s Hospital of New York Presbyterian, Columbia University, New York, New York

Abstract

Objective. Pediatricians are encountering body composition information more frequently, with percentage of body fat (%BF) measurement receiving particular attention as a result of the obesity epidemic. One confounding issue is that different methods may yield different %BF results in the same person. The objective of this study was to compare dual-energy X-ray absorptiometry (DXA) with the criterion 4-compartment model (4-CM) for measurement of %BF in a large pediatric cohort and to assist pediatricians in appropriate interpretation of body composition information by recognizing differences between techniques. Methods. Height, weight, anthropometrics, body density by underwater weighing, total body water by deuterium dilution, and bone mineral content and %BF by DXA (Lunar DPX/DPX-L) were measured in 411 healthy subjects, aged 6 to 18 years. Values for %BF by 4-CM and DXA were compared using regression analysis. Results. The mean ± standard deviation values for %BF by DXA (22.73% ± 11.23%) and by 4-CM (21.72% ± 9.42%) were different, but there was a strong relationship between the 2 methods (R2 = 0.85). DXA underestimated %BF in subjects with lower %BF and overestimated it in those with higher %BF. The relationship between the 2 methods was not affected by gender, age, ethnicity, pubertal stage, height, weight, or body mass index. The standard error of the estimate was 3.66%. Conclusion. This analysis demonstrates a predictable relationship between DXA and 4-CM for %BF measurement. Because of its ease of use, consistent relationship with 4-CM, and availability, we propose that DXA has the capacity for clinical application including prediction of metabolic abnormalities associated with excess %BF in pediatrics.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3