Pulmonary Effect of Inhaled Furosemide in Ventilated Infants With Severe Bronchopulmonary Dysplasia

Author:

Kugelman Amir1,Durand Manuel2,Garg Meena1

Affiliation:

1. From the Division of Neonatology and Pediatric Pulmonology, Children's Hospital, Los Angeles; and

2. Division of Neonatology, Los Angeles County and University of Southern California Medical Center, University of Southern California, School of Medicine, Los Angeles.

Abstract

Background. When administered parenterally, furosemide, a loop diuretic, results in improved lung compliance and decreased airway resistance in infants with bronchopulmonary dysplasia (BPD). However, furosemide-induced diuresis results in hypokalemia, chloride deficiency, hypercalciuria, nephrocalcinosis, and rickets. In patients with asthma, inhaled furosemide has recently been demonstrated to inhibit the bronchoconstrictive effects of exercise, cold air hyperventilation, and antigen challenge. We hypothesized that inhaled furosemide will result in improved pulmonary mechanics in ventilated infants with BPD and will prevent the systemic complications of parenteral furosemide. Objective. To determine the efficacy and safety of a single dose of inhaled furosemide on pulmonary mechanics in infants with severe BPD who are ventilator dependent at 21 days of age. Design and Methods. A randomized, double-blind, crossover study was performed on 9 infants with BPD, each serving as his own control. Each patient was randomized to receive an aerosol dose of furosemide (1 mg/kg in 2 mL of saline) or placebo (2 mL of saline) on the first day of the study and the other agent the following day of the study. Pulmonary mechanics were measured before and 1 and 2 hours after the inhalation using the Pulmonary Evaluation and Diagnostics System. Results. Gestational age (mean ± SEM) was 29 ± 1 weeks; birth weight was 1.1 ± 0.1 kg; age at study was 47 ± 6 days; and weight at study was 1.8 ± 0.2 kg. There was no significant change in the pulmonary function measurements before treatment and 1 or 2 hours after treatment with either placebo or furosemide. Baseline and 2-hour values were: dynamic compliance (mL/cm H2O per kilogram): 0.46 ± .03 to 0.50 ± .03 (placebo) and 0.50 ± 0.02 to 0.51 ± 0.02 (furosemide); dynamic resistance (cm H2O/L per second): 118 ± 9 to 106 ± 7 (placebo) and 111 ± 8 to 105 ± 7 (furosemide); and tidal volume (mL/kg): 8.6 ± 0.5 to 8.9 ± 0.5 (placebo) and 8.9 ± 0.2 to 9.4 ± 0.3 (furosemide). Conclusion. We conclude that, under the conditions of our study, a single dose of 1 mg/kg inhaled furosemide does not improve the pulmonary mechanics in ventilator-dependent infants with severe BPD.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3