Mainstream End-tidal Carbon Dioxide Monitoring in the Neonatal Intensive Care Unit

Author:

Rozycki Henry J.1,Sysyn Gregory D.1,Marshall M. Kathy1,Malloy Raymond2,Wiswell Thomas E.2

Affiliation:

1. From the Departments of Pediatrics and Respiratory Care,Medical College of Virginia, Virginia Commonwealth University, Richmond, Virginia; and

2. Thomas Jefferson University, Philadelphia, Pennsylvania.

Abstract

Background. Continuous noninvasive monitoring of arterial carbon dioxide (CO2) in neonatal intensive care unit (NICU) patients would help clinicians avoid complications of hypocarbia and hypercarbia. End-tidal CO2monitoring has not been used in this population to date, but recent technical advances and the introduction of surfactant therapy, which improves ventilation-perfusion matching, might improve the clinical utility of end-tidal monitoring. Objective. To determine the accuracy and precision of end-tidal CO2 monitoring in NICU patients. Design. Nonrandomized recording of simultaneous end-tidal and arterial CO2 pairs. Setting. Two university NICUs. Patients. Forty-five newborn infants receiving mechanical ventilation who had indwelling arterial access, and a predefined subsample of infants who were <1000 g birth weight, <8 days of age, and who received surfactant therapy (extremely low birth weight [ELBW] <8). Outcome Measures. The correlation coefficient, degree of bias, and 95% confidence interval were determined for both the overall population and the ELBW <8 subgroup. Those factors which significantly influenced the bias were identified. The ability of the end-tidal monitor to alert the clinician to instances of hypocarbia or hypercarbia was determined. Results. There were 411 end-tidal/arterial pairs analyzed from 45 patients. The correlation coefficient was 0.833 and the bias was −6.9 mm Hg (95% confidence interval, ±11.5 mm Hg). The results did not differ markedly in the ELBW <8 infants. Measures of the degree of lung disease, the ventilation index and the oxygenation index, had small influences on the degree of bias. This type of capnometry identified 91% of the instances when the arterial CO2 pressure was between 34 and 54 mm Hg using an end-tidal range of 29 to 45 mm Hg. End-tidal values outside this range had a 63% accuracy in predicting hypocarbia or hypercarbia. Conclusion. End-tidal CO2 monitoring in NICU patients is as accurate as capillary or transcutaneous monitoring but less precise than the latter. It may be useful for trending or for screening patients for abnormal arterial CO2 values.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

Reference32 articles.

1. Pulse oximetry in neonatal intensive care.;Dziedzec;Clin Perinatol,1989

2. Hypocarbia before surfactant therapy appears to increase bronchopulmonary dysplasia risk in infants with distress syndrome.;Garland;Arch Pediatr Adolesc Med,1995

3. Hypocarbia and cystic periventricular leukomalacia in premature infants.;Fujimoto;Arch Dis Child,1994

4. Response of cerebral blood volume to changes in arterial carbon dioxide tension in preterm and term infants.;Wyatt;Pediatr Res,1991

5. Perinatal factors and periventricular-intraventricular hemorrhage in preterm infants.;Van DeBor;Am J Dis Child,1986

Cited by 86 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3