Evaluation of CTV to PTV Margin for Head and Neck Cancer with Daily Setup Using MVCBCT Imaging

Author:

Bessarabova K. S.1,Mikhailova A. V.1,Lebedenko I. M.1,Krylova T. A.1

Affiliation:

1. N.N. Blokhin National Medical Research Center of Oncology

Abstract

Purpose: Geometrical inaccuracies of setup using MV-CBCT imaging for patients with head and neck cancer were evaluated. Possibility of modifying of CTV to PTV margin while delineation of such tumors was estimated. Materials and methods: Additional adjustment of simulation kV CT pictures with MV-CBCT images received during the implementation of the online protocol was conducted for 35 patients with head and neck cancer. Offline analysis revealed the discrepancy in the results of online correction and offline analyses. CTV to PTV margin considering daily setup was computed. Results: Obtained values of CTV to PTV margin: 2.4 mm in Vrt, 2.1 mm in Lng and 2.5 mm in Lat. Upward variations from 5 mm margin used in unit were registered for 2 patients. Conclusions: Reduction of CTV to PTV margin up to 2.5 mm is precarious because CTV dose coverage is not reasonable for all patients. Implementation of routine work practice in Off-line Review is required for identification of problem cases and determination of individual CTV to PTV margin.

Publisher

Association of Medical Physicists in Russia

Reference7 articles.

1. ICRU: Prescribing, recording and reporting photon-beam intensity-modulated radiation therapy. ICRU Report 83.International Commission on Radiation Units and Measurements. 2010.

2. Михайлова АВ, Булычкин ПВ, Ткачев СИ. Коррекция позиционирования пациентов при лечении больных рецидивом рака предстательной железы. Медицинская физика.2015; 4(66): 42-6. [Mikhailova AV, Bulychkin PV, Tkachev SI. Correction of patient positioning in the treatment of patients with recurrent prostate cancer. Medical Physics. 2015; 4(66): 42-6 (in Russian)].

3. Geometric Uncertainties in Radiotherapy. - London, UK: The British Institute of Radiology, 2003.

4. Stroom JC, de Boer HC, Huizenga H. et al. Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability.Int. J. Radiat. Oncol. Biol. Phys. 1999: 43 (4): 905-19.

5. Gupta T. et al. Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device. Radiation Oncology. 2007; 2(1): 1-8.