Accuracy of CT Perfusion–Based Core Estimation of Follow-up Infarction

Author:

Sarraj AmrouORCID,Campbell Bruce C.V.ORCID,Christensen Soren,Sitton Clark W.,Khanpara Shekhar,Riascos Roy F.,Pujara Deep,Shaker FarisORCID,Sharma Gagan,Lansberg Maarten G.ORCID,Albers Gregory W.,

Abstract

Background and ObjectivesTo assess the accuracy of baseline CT perfusion (CTP) ischemic core estimates.MethodsFrom SELECT (Optimizing Patient Selection for Endovascular Treatment in Acute Ischemic Stroke), a prospective multicenter cohort study of imaging selection, patients undergoing endovascular thrombectomy who achieved complete reperfusion (modified Thrombolysis In Cerebral Ischemia score 3) and had follow-up diffusion-weighted imaging (DWI) available were evaluated. Follow-up DWI lesions were coregistered to baseline CTP. The difference between baseline CTP core (relative cerebral blood flow [rCBF] <30%) volume and follow-up infarct volume was classified as overestimation (core ≥10 mL larger than infarct), adequate, or underestimation (core ≥25 mL smaller than infarct) and spatial overlap was evaluated.ResultsOf 101 included patients, median time from last known well (LKW) to imaging acquisition was 138 (82–244) minutes. The median baseline ischemic core estimate was 9 (0–31.9) mL and median follow-up infarct volume was 18.4 (5.3–68.7) mL. All 6/101 (6%) patients with overestimation of the subsequent infarct volume were imaged within 90 minutes of LKW and achieved rapid reperfusion (within 120 minutes of CTP). Using rCBF <20% threshold to estimate ischemic core in patients presenting within 90 minutes eliminated overestimation. Volumetric correlation between the ischemic core estimate and follow-up imaging improved as LKW time to imaging acquisition increased: Spearman ρ <90 minutes 0.33 (p= 0.049), 90–270 minutes 0.63 (p< 0.0001), >270 minutes 0.86 (p< 0.0001). Assessment of the spatial overlap between baseline CTP ischemic core lesion and follow-up infarct demonstrated that a median of 3.2 (0.0–9.0) mL of estimated core fell outside the subsequent infarct. These regions were predominantly in white matter.DiscussionSignificant overestimation of irreversibly injured ischemic core volume was rare, was only observed in patients who presented within 90 minutes of LKW and achieved reperfusion within 120 minutes of CTP acquisition, and occurred primarily in white matter. Use of a more conservative (rCBF <20%) threshold for estimating ischemic core in patients presenting within 90 minutes eliminated all significant overestimation cases.Trial Registration InformationClinicalTrials.gov:NCT03876457.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical)

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3