Seizure Detection in Continuous Inpatient EEG

Author:

Ganguly Taneeta Mindy,Ellis Colin A.,Tu DanniORCID,Shinohara Russell T.,Davis Kathryn A.ORCID,Litt BrianORCID,Pathmanathan JayORCID

Abstract

Background and ObjectivesThe aim of this work was to test the accuracy of Persyst commercially available automated seizure detection in critical care EEG by comparing automated seizure detections to human review in a manually reviewed cohort and on a large scale.MethodsAutomated seizure detections (Persyst versions 12 and 13) were compared to human review in a pilot cohort of 229 seizures from 85 EEG records and then in an expanded cohort of 7,924 EEG records. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for individual seizures (pilot cohort) and for entire records (pilot and expanded cohorts). We assessed EEG features associated with the accuracy of automated seizure detections.ResultsIn the pilot cohort, accuracy of automated detection for individual seizures was modest (sensitivity 0.50, PPV 0.60). At the record level (did the recording contain seizures or not?), sensitivity was higher (pilot cohort 0.78, expanded cohort 0.91), PPV was low (pilot cohort 0.40, expanded cohort 0.08), and NPV was high (pilot cohort 0.88, expanded cohort 0.97). Different software versions (version 12 vs 13) performed similarly. Sensitivity was higher for records containing focal-onset seizures compared to generalized-onset seizures (0.93 vs 0.85, p = 0.012).DiscussionIn critical care continuous EEG recordings, automated detection of individual seizures had rates of both false negatives and false positives that bring into question its utility as a seizure alarm in clinical practice. At the level of entire EEG records, the absence of automated detections accurately predicted EEG records without true seizures. The true value of Persyst automated seizure detection appears to lie in triaging of low-risk EEGs.Classification of EvidenceThis study provides Class II evidence that an automated seizure detection program cannot accurately identify EEG records that contain seizures.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical)

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3