Abstract
We present the case of a 3-month-old boy who suffered bilateral pneumothoraces secondary to insufflation of oxygen into the endotracheal tube during the apnea test as part of brain death testing. Although rare, awareness of this potential complication of the apnea test is of particular importance in pediatric patients who have narrow endotracheal tubes because resistance to expiratory flow increases exponentially as lumen diameter decreases.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Reference9 articles.
1. Tension Pneumothorax during Apnea Testing for the Determination of Brain Death
2. Tension pneumothorax complicating apnea testing during brain death evaluation;Burns;J Clin Neurosci,2007
3. Brain death: bilateral pneumothorax and pneumoperitoneum after an apnoea test;Thery;Anaesth Crit Care Pain Med,2019
4. Apnea testing for the determination of brain death: a systematic scoping review;Busl;Neurocrit Care,2020
5. Problems associated with the apnea test in the diagnosis of brain death;Sapsonik;Neurol India,2004