Late tibial interference screw extrusion following anterior cruciate ligament reconstruction: A case report

Author:

Milam Rachel J1,Drayer Nicholas J2,Wallace Christopher S1,Kang Daniel G1,Masini Brendan D1

Affiliation:

1. Madigan Army Medical Center

2. Winn Army Community Hospital, Department of Orthopaedics, Fort Stewart, GA

Abstract

Introduction Interference screws are used as back-up fixation in anterior cruciate ligament reconstructions. Historically these were composed of metal, but recently surgeons have switched to using bioabsorbable screws as they cause less symptoms and are biomedically advantageous. Usually these screws are absorbed by the body within one to two years after surgery. Case Presentation A 32-year-old male presented with aseptic extrusion of his intact tibial bioabsorbable interference screw eight years following successful anterior cruciate ligament reconstruction. Management and Outcomes Patient underwent laboratory evaluation and magnetic resonance imaging to rule out infection as an underlying cause. He went on to heal the wound without complication. Conclusion Late aseptic extrusion of tibial interference screw can occur; however, infectious etiologies should be carefully ruled out.

Publisher

Open Medical Publishing

Subject

Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3