Abstract
Reduction of drift in high rise structures is necessary to prevent unsightly plaster cracks and minimize the psychological effects of unnerving movements and frightening noises. The purpose of lateral load bracing systems is to resist lateral forces due to wind and earthquake. Wind or seismic bracing systems may be classified as X brace, K brace, knee brace, and rigid frame. These systems are used in building core regions, as between elevator or duct shafts and adjacent to passageways or corridors. Shear walls are often selected for structures with large column spacings when lateral forces can no longer be resisted by the floor slabs alone. The extent of joint fixity provided by connections becomes a primary consideration in the design of rigid frame bracing.
Publisher
American Institute of Steel Construction
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献