Subtle errors of bladder wall thickness measurement have a significant impact on the calculation of ultrasound-estimated bladder weight. A pilot study

Author:

Sakalis Vasileios I.,Sfiggas Vasileios,Vouros Ioannis,Salpiggidis Georgios,Papathanasiou Athanasios,Apostolidis Apostolos

Abstract

Aims: Ultrasound-estimated bladder weight (UEBW), is an emerging diagnostic tool, which has been used in both males and females with lower urinary tract dysfunction. The currently acknowledged UEBW calculation methods rely on the accurate measurement of bladder wall thickness (BWT). We aim to identify if subtle errors in BWT measurement have a significant impact on UEBW calculations.Materials and methods: Twenty patients were randomly selected from an overactive bladder patient cohort. The primary endpoint was to identify the range of false BWT measurements outside which significant changes in UEBW calculation occur. We used the Kojima method and a semi-automatic 3-D model that is based on Chalana’s principle. Measurements were performed using the correct BWT and a series of faulty calculations from +0.5 mm to -0.5 mm using steps of 0.05 mm from true BWT. The effect of a fixed 0.5 mm BWT error was checked in bladder volumes above and below 250 ml and in three UEBW groups (<35 gr; 36-50 gr; >51gr).Results: BWT measurement errors above 0.25 mm cause statistically significant changes in UEWB calculation when a 3-D model is used and errors above 0.15 mm when Kojima’s method is used. At a fixed BWT error of 0.5 mm and bladder volume <250 ml, there is a 23.76% deviation from true UEBW, while at volumes >250 ml the deviation is 32.72%. The deviation is inversely proportional to the UEBW result, and heavier bladders deviate less.Conclusions: UEBW is a promising diagnostic tool, but small errors in BWT measurement might cause significant deviation from the true values. A 3-D calculation model appears to minimize such risks.

Publisher

SRUMB - Romanian Society for Ultrasonography in Medicine and Biology

Subject

Acoustics and Ultrasonics,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3