Splenogonadal fusion evaluation using Contrast Enhanced Ultrasound and Elastography. A case report.
-
Published:2019-08-31
Issue:3
Volume:21
Page:356
-
ISSN:2066-8643
-
Container-title:Medical Ultrasonography
-
language:
-
Short-container-title:Med Ultrason
Author:
Grosu Sergio,Rübenthaler Johannes,Knösel Thomas,Trottmann Matthias,Marcon Julian,Clevert Dirk-Andre
Abstract
We present the case of splenogonadal fusion in a 53-year-old male patient assessed by ultrasound and MRI, confirmed by pathologic examination. In addition to B-mode and colour-coded Doppler ultrasound, shear wave elastography and CEUS were performed and are presented in detail. Splenogonadal fusion is a rare congenital anomaly presumably caused by an abnormal attachment of splenic tissue to the gonad during gestation. Diagnosis is challenging for clinicians and in unclear cases splenogonadal fusion might cause unnecessary orchiectomies with benign pathologic results. Ultrasound is the first-line imaging modality in the diagnosis of testicular pathologies. This case report summarizes all available modern ultrasound imagingtechnologies and highlights the possibilities for the diagnosis of splenogonadal fusion.
Publisher
SRUMB - Romanian Society for Ultrasonography in Medicine and Biology
Subject
Acoustics and Ultrasonics,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Cited by
4 articles.