Abstract
Aims: The aim of this study was to compare the diagnostic performance of superb microvascular imaging (SMI) and power Doppler imaging (PDI) for the differentiation of intraductal breast lesions.Materials and methods: A total of 54 intraductal breast lesions (39 benign, 10 atypical, and 5 malignant) in 53 patients were examined using B-mode ultrasonography, PDI, and SMI. Vascularity grading, distribution of microvessels, and penetrating vessels were evaluated using each Doppler technique. The diagnostic performances of both methods were compared.Results: SMI was more efficient in detecting flow signals than PDI (p=0.004). The highest diagnostic accuracy rates were achieved with SMI using vascular grading. When hypervascularity was used as a cut-off value to differentiate malignant and atypical lesions from benign lesions, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 66.6%, 80.7%, 66.6%, 80.7%, and 75.6%for PDI, and 86.6%, 76.9%, 68.4%, 90.9%, and 80.4% for SMI, respectively. Conclusions: SMI is more sensitive than PDI for detecting subtle blood flow in intraductal breast lesions with statistical significance. This novel and promising vascular imaging technique may be helpful in B-mode ultrasonography to distinguish intraductal breast lesions.
Publisher
SRUMB - Romanian Society for Ultrasonography in Medicine and Biology
Subject
Acoustics and Ultrasonics,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Cited by
24 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献