How to diagnose renal artery stenosis correctly using ultrasound? Evaluation of results of renal arteries duplex ultrasonography examinations

Author:

Zhu Rong,Xu Zhonghui,QI Zhenhong,YE We,Wang Jian,Kong Jing,Jin Jin,Li Jianchu

Abstract

Aim: Renal artery duplex ultrasonography (RDU) is an effective and non-invasive screening test in diagnosing renal artery stenosis. The discordance of results in multiple RDU is common. We aim to evaluate the discordance and the reasons for discordance between diagnoses and measurements from multiple RDU examinations.Material and method: A retrospective study was performed in 64 examinations of renal arteries from 32 patients that were referred for two or more RDU examinations and renal artery digital subtraction angiography (DSA) within six months, between August 2013 and January 2016. Using DSA as gold standard, we divided the renal arteries into three groups: discordant (one diagnosis of RDU was correct and one was wrong), misdiagnosed (neither RDU diagnosis was correct) and correct (both RDU diagnoses were correct) groups.We evaluated the discordance and reasons for discordance of diagnoses and measurements from multiple RDU examinations. Results: Among 64 renal arteries included in this study, 37 renal arteries had two correct diagnoses, 19 renal arteries had two discordant diagnoses, and eight renal arteries were misdiagnosed twice by RDU. The discordance of peak systolic velocity (PSV), the ratio between PSV in the renal artery with stenosis and PSV in the aorta (RAR), and tardus-parvus waveform measurements were clearly higher in the discordant diagnoses group than in the correctly diagnosed group. The most common reason for a discordant diagnosis was failure in obtaining correct tardus-parvus waveforms of the interlobar artery (26.31%). Themost common reason for misdiagnosis was the presence of an extremely severe stenosis with an atrophic kidney (31.25%). Overall, 87.50% of patients underwent RDU examinations had correct diagnoses of stenosis or occlusion at least once (including location and degree), as confirmed by DSA.Conclusions: Our study indicates that standard operating procedures and improvements in examination technique by ultrasound doctors could reduce the discordance between multiple tests. 

Publisher

SRUMB - Romanian Society for Ultrasonography in Medicine and Biology

Subject

Acoustics and Ultrasonics,Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3